Bacharach 2072-0400 Manual De Usuario

Descargar
Página de 40
Operation  
MAC2000  
3.7  Refrigerant Management System 
 
The MAC2000’s Refrigerant Management System tracks all aspects of 
refrigeration usage, which can significantly help in the management 
of an A/C repair business.  In addition, the unit’s software allows a 
business to meet new federal regulations requiring strict records of 
refrigerant usage.  
 
Refrigerant measurement during charging is extremely accurate. In 
the recovery mode, however, accuracy is plus or minus 3 ounces based 
on variations in air temperature and pressure. 
 
Uses of the refrigerant data include: 
 
• 
Improved record keeping 
• 
Accurate determination of net profits for your business 
• 
Reduced billing errors 
• 
Minimized refrigerant loss from leaks and theft 
• 
Reduced technician errors 
 
Enter the Refrigerant Management mode as follows: 
 
From the Main menu, press the Next menu function key twice to 
display Menu 3; then press Refri Data to select the Refrigerant 
Management Mode. 
 
The first screen displays the following information in the “Last job 
refrigerant management data
” screen:  
 
  Date & time ......Date and time the job was started 
  Mode  .................Lists what job was performed: recovery, charging, 
vacuum, or flush 
  Run time ...........Time it took to complete the job 
  Status  ...............Describes whether the job was normally completed 
or interrupted 
  Recovered  .........Weight of refrigerant recovered from vehicle 
  Charged  ............Weight of refrigerant charged into vehicle 
  Added ................Weight of refrigerant transferred from the external 
source tank to the internal storage tank 
 
Pressing Next displays the following data in the “Total refrigerant 
management data
” screen: 
 
•  Total # Of Jobs ..Total time spent doing all jobs, and number of all 
jobs that were performed 
  Total Recovery...Time spent doing recovery and number of times it 
was performed 
  Total Vacuum....Time spent doing evacuation and number of times 
it was performed 
  Total Charge .....Time spent charging and number of times it was 
performed 
24 