proper functioning. It is strongly recommended that 
a qualified service technician inspect the basic items 
listed below every year.
 
a.  Ignition control
 
b.  Ignitor
 
c.  Water temperature control
 
d.  Automatic gas valve
 
e.  Pressure switches and tubing
 
f. 
Blower
 
g.  High limit
 
h.  Pump (if required)
 
i. 
Relays
 
j. 
Flow switch
 
k.  Gas train
 
l. 
Control components
7.2.1  Burners
Close main manual gas valve before proceeding. 
Checking the burners for debris - Remove the ignitor/
burner access panel and ignitor, and inspect the 
burners through the ignitor hole using a flashlight to 
illuminate. If there is any indication of debris on the 
burners that is visible, all the burners will need to be 
inspected more thoroughly. Remove the gas manifold 
assemblies and the burner assemblies. Inspect the 
burners. Clean burners, if necessary, by blowing 
compressed air from the outside of the burners into 
the center of the burner. A dirty burner may be an 
indication of improper combustion or dirty combustion 
air. Determine the cause, and correct. Replace the 
burners in the reverse order.
7.2.2  Filter
The filter used in the Brute Deluxe is washable 
and has an 80% arrestance rating. Since the filter is 
washable, it will only need replacement occasionally. 
If filter replacement is needed, it should only be 
replaced with a factory part. Inspect the air filter 
monthly, or more often in dirty environments. If there 
is debris on the air filter, remove it from the filter 
frame, and wash it with mild soap and water. Ensure 
that the filter is completely dry before reinstalling.
7.2.3  Gas Valves
The gas valves are designed to operate with 
supply pressures of 4-13 in. w.c. (1.0 to 3.2 kPa).
To remove a valve, shut off 120-volt power 
and the manual gas shutoff valve. Remove the front 
panels from the unit. Disconnect the wires to the valve. 
Disengage the unions before and after the valve, and 
remove the valve. Pull the pipe nipples from the inlet 
and outlet of the valve, and clean the threads on the 
pipe nipples for reuse. Apply new tape or pipe dope 
to the pipe nipples (threaded joints should be coated 
with piping compound resistant to action of liquefied 
petroleum gas), and reinstall in reverse order. Turn 
on manual gas shutoff valve and 120 volt power and 
check appliance operation and tightness of gas valve 
connections. 
7.2.4  Manual Reset High Limit Control
The high limit switch is a manual reset, non-
adjustable switch with a remote bulb-type sensor. 
Switches for water heaters and low temperature boiler 
models are set at 200°F. Switches for standard boilers 
are set at 240°F.
The control is located behind the front door, on a 
panel in front of the blower. The probe is in the outlet 
side of the header.
To reset the switch, unscrew the black cover that 
is over the reset button, and push the button. Replace 
the cover after the switch is reset.
To replace, shut off power to the appliance. 
Remove the cover that is over the button, and remove 
the nut that is around the button. Pull the control 
through the panel, and remove the spade terminals. 
Replace in reverse order.
7.2.5  Ignition Control
The ignition control controls the hot surface 
ignitor and proves that the flame signal is appropriate 
for powering the gas valves. It also controls the 
blower’s pre-purge and post-purge. 
To replace a control, shut off the 120-volt power 
to the appliance. Remove the cover from the control 
panel. Remove the electrical connectors from the 
ignition control. Take out the controller’s mounting 
screws, and pull the controller out. Replace in reverse 
order.
7.2.6  Ignitor
The ignitor used is a 120v “Hot Surface” type. 
It is energized whenever there is a call for heat and 
switched off when ignition is established and the flame 
has been sensed. To replace the ignitor, shut off the 
120-volt power to the appliance, remove the ignitor/
burner access panel, disconnect the Molex connector, 
remove the two mounting screws on the ignitor flange, 
and pull the ignitor out. Install in reverse order, always 
using a new ignitor gasket with the replacement 
ignitor.
 Caution
Ignitor gets hot. To avoid injury, handle the ignitor 
with caution.
 Attention
Le dispositif d’allumage devient très chaud. 
Manipulez le dispositif d’allumage avec précaution.
7.2.7 Transformer
The Brute Deluxe’s transformer is not capable 
of supplying control voltage for external devices such 
as zone valves, which must have their own separate 
power supply. Should a transformer need replacing, 
shut off the 120-volt power. Unplug the transformer