Ariston System A 24 RFF Manual De Usuario
39
Menu - 2 - Boiler conditions
Indicates the conditions or the configurations of the boiler
5 ”
Menu - 1 - Default register
Record the last 10 defaults
x times
once
DISPLAY
ACTION
CONFIGURATION
Note -- is displayed if no default is recorded
Section
Digit 1
Digit 2
Digit 3 and 4
Last default occured
1
0
code from 01 to 99
Last but one default occurred
1
1
code from 01 to 99
...
1
...
code from 01 to 99
Last default occurred before the previous
one
one
1
9
code from 01 to 99
x times
Section
Digit 1
Digit 2
Digit 3 and 4
Software version of display PCB
2
0
code from 01 to 99
Software version of main PCB
2
1
code from 01 to 99
Flue type
2
2
4 : Condensation
Fan speed (in hundreds of rpm)
2
3
from 01 to 99
Theoretical position of the 3 way valve
System plus only
System plus only
2
4
0 : DHW
1 : CH
DHW flow temperature in °C
2
5
from 01 to 99
CH flow temperature in °C
2
7
from 01 to 99
CH return temperature in °C
2
8
from 01 to 99
Outside temperature in °C
2
9
from 01 to 99