Stove Installation 
(for qualified installers only)
15
© Travis Industries
100-01177
4060802
Mobile Home Requirements
 
Outside air must be installed - see "Outside Air Requirements" on page 13
 
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC connector with AMERI-TEC UL 103 HT chimney
DURAVENT model DVL connector with DURAVENT UL 103 HT chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel HP connector with I.C.C. UL 103 HT chimney
METALFAB model DW connector with METALFAB UL 103 HT chimney
OLIVER MACLEOD PROVENT model PV connector with OLIVER MACLEOD UL 103 HT chimney
SECURITY model DP connector with SECURITY UL 103 HT chimney
SELKIRK model DSP connector with SELKIRK UL 103 HT chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
 
Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
A
B
F
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
C
Measure clearances from the 
nearest edge of the stove top.
D
E
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
C
Figure 11
Minimum Clearance
(See the illustration above)
Reduced Clearance
Connector
A
Sidewall to stove
18.00”
B
Backwall to stove
20.75”
C
Cornerwall to stove
14.00”
D
Connector to sidewall
28.25”
E
Connector to backwall
14.00”
F
Connector to cornerwall
17.50”
 
If using offsets, use the connector clearance listed in Figure 12,
not the connector manufacturer's clearance.
 
The appliance must be secured to the floor (consult your
building official).  Secure the outside air boot to the floor and
stove to insure the stove does not dislocate.
 
Mobile home installations require a spark arrester at the
chimney termination.
 
The appliance must be grounded to the chassis of the mobile
home (consult your building official).
 
WARNING:DO NOT INSTALL IN SLEEPING ROOM.
 
CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
12” Min.
Connector Clearance 
(as outlined above)
Stove Clearance 
(as outlined above)
A
A
Figure 12