Stove Installation 
(for qualified installers only)
17
© Travis Industries
100-01179
4060926
Hearth Stove Direct
Connection
NOTE:
Direct connections require
installation of an airtight,
non-combustible block-off
plate or damper adapter.
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AA
AA
AA
AA
AA
AA
Block-off plate or 
damper adapter 
Remove damper 
or wire it open
Airtight 
Insulated 
Clean-Out
Stainless steel 
chimney connector 
must Extend 1' past 
the block-off plate or 
to the flue liner  
NOTE: The chimney must have a clay 
tile liner.  If it does not, the installation 
must use a positive connection (full 
reline).  The entire fireplace and 
chimney must be clean, undamaged, 
and meet all local building codes (UBC, 
etc.).  Damage must be repaired prior 
to installation.  The chimney must be 
15' to 33' tall.
Clay 
Liner
Floor Protection
(See the section 
"Floor Protection 
Requirements" for 
more details)
Combustible Mantle
Min. 18" 
See the section 
"Stove Placement 
Requirements" for 
minimum clearances 
required.
Max. 8”
Figure 15
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation
requires a UBC approved
masonry connector or
other method approved by
the NFPA 211 standard.
See Chimney Connector
Requirements on page 10
for further details.
Make sure the 
clean-out seals in 
place.
Clay Liner
See the section "Stove 
Placement Requirements" for 
minimum clearances required.
Min. 18" 
clearance 
to ceiling
This type of 
installation requires 
a UBC approved 
masonry connector 
or a factory built 
(U.L. Listed) wall 
thimble.
Chimney connector sections
NOTE: The chimney must have a 
clay tile liner.  If it does not, the 
installation must use a positive 
connection (full reline).  The 
entire fireplace and chimney must 
be clean, undamaged, and meet 
all local building codes (UBC, 
etc.).  Damage must be repaired 
prior to installation.  The chimney 
must be 15' to 33' tall.
See the section 
"Floor Protection 
Requirements" 
Figure 16