VENT GRAPH (cont'd) 
Note:  Maximum propane horizontal vent run is 13' (3960mm) when the vertical vent rise is 10' (3048mm) 
Note:  Minimum vertical rise is 2' (908 mm) 
Note:  Minimum horizontal run is 11" (279mm) on a vertical to horizontal installation. 
 
Note:  Minimum wall thickness 4" (100mm) 
Note:  Maximum wall thickness 20" (508mm). 
 
FIGURE 19:  BAYVUE DV VENT GRAPHS, MODEL DV 30 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A vent shall not terminate: 
A. 
Within six feet (1.8 meters) of a mechanical air supply inlet to a building. 
B. 
Above a utility meter within three feet (1 meter) horizontally of its vertical center line. 
C. 
Within six feet (1.8 meters) of any gas service regulator vent outlet. 