FIGURE 12:  BLOWER FAN 
 
FAN INSTALLATION 
The Bayvue DV comes standard with the fan kit installed.  The Fan Kit consists of a blower system.  The 
fan is connected to the Bayvue DV’s wiring harness.  The Bayvue DV is pre-wired for and includes a 
rheostat (speed control), a heat activated thermo-disc and a 120 volt receptacle.  The fan slips inside the 
back of the pedestal into two slides mounted to the bottom of the firebox. 
 
DIRECT VENT INSTALLATION 
GENERAL 
Country Flame Bayvue DV product is approved for side wall vent or vertical vent through a roof.  Only 
Simpson Dura Vent chimney components or Selkirk Model Direct-Temp chimney components may be 
used with this product.  Simpson Dura Vent chimney vent products are listed in this manual to assist with 
vent installation selection.  Read all these instructions carefully before starting the installation.  Failure to 
follow instructions may create a fire or other safety hazard, and will void the product warranty.  Be sure to 
follow installation instructions and maintain proper venting and maintain clearances to combustible that 
will vary from one installation to another. 