Country Flame DV 30 Manual De Usuario

Descargar
Página de 48
STEP 3 
Remove shingles or other roof covering as necessary to cut the rectangular hole for the support 
box.  Cut the hole 1/8" larger than the support box outline. 
 
STEP 4 
Lower the support box through the hole in the roof until the bottom of the support box protrudes 
at least 2 inches below the ceiling.  Align the support box in place through the inside walls and 
into the roof sheathing. 
 
STEP 5 
Using tin snips, cut the support box from the top corners down to the roof line, and fold the 
resulting flaps over the roof sheathing.  Before nailing it to the roof, run a bead of non-hardening 
mastic around the top edges of the support box, to make a seal between the box and the roof.  
Clean out any combustible material from inside the support box. 
 
STEP 6 
Complete the cathedral ceiling installation by following the same procedures outlined in Steps 4 
through 9 for vertical terminations. 
 
MAINTENANCE 
The frequency of performing fireplace maintenance depends on site-specific conditions and the frequency 
of homeowner use of this product.  Country Flame recommends that a certified service technician perform 
an annual check-up on an appliance prior to the start of each heating season.  Follow the general guidelines 
provided below for each specific maintenance task.  If there are any questions about maintenance or proper 
service, contact the local Country Flame dealer or a certified service technician for clarification of any 
issue.
 
IMPORTANT: TURN OFF THE FIREPLACE AND SHUT OFF THE GAS BEFORE SERVICING 
ANY FIREPLACE. 
 
SPECIFIC TASKS 
CLEANING BURNERS AND CONTROLS 
FREQUENCY: 
Once during annual inspection. 
PERFORMED BY: Qualified service technician. 
TASK PERFORMED: Clean the control compartment.  Remove and clean logs (careful not to damage 
ceramic logs).  While logs are removed, clean and inspect 3 burners, inspect and clean pilot assembly, and 
inspect and clean surrounding burner area. 
 
REPLACE OLD EMBERS 
FREQUENCY: 
Once during annual inspection. 
PERFORMED BY: Qualified service technician. 
Version 1.0h 
32 
TASK PERFORMED: Replace ember material with new ember material. Additional ember material can 
be purchased from a local authorized Country Flame Dealer. (Only use genuine Country Flame ember 
material)