Cooper Lighting 224T5HO Prospecto

Descargar
Página de 2
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/02/2008 3:16:54 PM
Specifications and Dimensions subject to change without notice.
ADF032747
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
2RDI
C o e f f i c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l   V C P   P e r c e n t a g e s
Height Along
Height Across
Room Size (Ft.)
8.5'
10.0'
8.5'
10.0'
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
||
C a n d e l a
Angle
Along II
45
o
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2RDI-224T5RPD
Electronic Ballast
(2) F24T5HO/830
Lamps 
1750 Lumens
Spacing criterion:
(II) 1.3 x mounting
height,  (
⊥) 1.3 x
mounting height
Efficiency 61.7% 
Test Report:
2RDI224T5RPD.IES
LER = FL39
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $6.11
631 
631 
631
630 
630 
629
622 
623 
625
608 
612 
616
588 
596 
604
563 
576 
589
533 
553 
570
497 
525 
549
457 
494 
524
412 
460 
496
364 
424 
466
312 
385 
433
257 
344 
398
202 
302 
360
150 
259 
318
105 
215 
280
65 
175 
242
32 
134 
197
0
74  74  74  74 
72  72  72  72 
69  69  69 
66  66  66 
63  63  63 
62
66  62  59  56 
64  61  58  55 
58  55  53 
55  53  52 
53  52  50 
49
59  53  48  44 
57  52  48  44 
50  46  43 
48  45  42 
46  43  41 
39
54  46  41  36 
52  45  40  36 
43  39  35 
42  38  35 
40  37  34 
33
49  41  35  30 
47  40  34  30 
38  33  30 
37  33  29 
35  32  29 
27
45  36  30  26 
43  36  30  26 
34  29  25 
33  29  25 
32  28  25 
23
41  33  27  22 
40  32  26  22 
31  26  22 
30  25  22 
29  25  22 
20
38  29  24  20 
37  29  23  20 
28  23  19 
27  23  19 
26  22  19 
18
36  27  21  18 
35  26  21  17 
26  21  17 
25  20  17 
24  20  17 
16
33  25  19  16 
32  24  19  16 
23  19  16 
23  19  15 
22  18  15 
14
31  23  18  14 
30  22  17  14 
22  17  14 
21  17  14 
21  17  14 
13
67
75
60
69
61
66
52
58
57
60
41
46
61
65
56
62
55
58
44
48
499
14.3
23.1
827
23.6
38.3
1519
43.4
70.3
2160
61.7
100.0
2160
61.7
100.0
C o e f f i c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l   V C P   P e r c e n t a g e s
Height Along
Height Across
Room Size (Ft.)
8.5'
10.0'
8.5'
10.0'
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
||
C a n d e l a
Angle
Along II
45
o
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2RDI-324T5RPD
Electronic Ballast
(2) F24T5HO/830
lamps
1750 lumens
Spacing criterion:
(II) 1.3 x mounting
height, (
⊥) 1.3 x
mounting height
Efficiency 63.9%
Test Report:
2RDI324T5RPD.IES
LER = FL42
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $5.72
1001 
1001 
1001
1002 
998 
996
989 
988 
988
967 
969 
974
935 
943 
953
894 
910 
926
847 
871 
894
789 
825 
858
724 
774 
816
652 
717 
770
575 
658 
722
491 
596 
669
403 
531 
611
314 
463 
549
230 
394 
482
159 
325 
417
97 
257 
354
48 
197 
291
0
76  76  76  76 
74  74  74  74 
71  71  71 
68  68  68 
65  65  65 
64
68  64  61  58 
66  63  60  57 
60  58  55 
58  55  54 
55  54  52 
51
61  55  50  46 
60  54  50  46 
52  48  45 
50  46  44 
48  45  43 
41
56  48  42  38 
54  47  42  38 
45  41  37 
43  39  36 
42  38  35 
34
51  42  36  32 
49  42  36  31 
40  35  31 
38  34  31 
37  33  30 
29
47  38  32  27 
45  37  31  27 
36  31  27 
34  30  26 
33  29  26 
25
43  34  28  24 
42  33  28  23 
32  27  23 
31  26  23 
30  26  23 
21
40  31  25  21 
39  30  25  21 
29  24  20 
28  24  20 
27  23  20 
19
37  28  22  18 
36  27  22  18 
27  22  18 
26  21  18 
25  21  18 
17
34  26  20  16 
34  25  20  16 
24  20  16 
24  19  16 
23  19  16 
15
32  24  18  15 
31  23  18  15 
23  18  15 
22  18  15 
21  17  15 
13
789
15.0
23.5
1306
24.9
38.9
2385
45.4
71.1
3353
63.9
100.0
3353
63.9
100.0
59
66
51
61
52
56
43
49
47
50
33
37
52
56
47
43
46
49
35
39
(1)
2' x 2' and 2' x 4' Center Lamp Shield models only.
SA M P L E N U M BE R: 2 R D I - 2 1 4 T 5 R P D - 1 2 0 V- E B T 1- U
N u m b e r
of Lamps
(Not included)
1= 1 Lamp
2= 2 Lamp
3= 3 Lamp
Wa tt a ge (Length)
1 4 T 5
= 14W T5 (24")
(1 )
2 4 T 5=24W T5HO (24")
(1 )
Voltage
( 2)
120V=120 Volt
277V=277 Volt
UNV=Universal
Voltage 120-277
Lamp Shield
R P D= Round Pe r f o r a t e d
Steel Below Ceiling Lamp
S h i e l d
R P D / T BW= Ro u n d
Perforated Below Ceiling
Lamp Shield withT h i n
Blade White Baff l e
Trim Type
L e ave Blank
= G r i d / L a y- i n
( S t a n d a r d )
= 2 ' W i d t h
Ovation Series
R D I=Recessed
Direct/Indirect
L e ave Blank=Center mounted
Lamps (standard)
O p t i o n s
GL
=Single Element Fuse
GM=Double Element Fuse
L a m p s=Lamps installed
F l e x=Flex installed
O p t i o n s
RIF1=Radio Interference
Suppressor
EQ-Clip-U=T-Bar EQ Clip
(Order Individually as Accessory.
Use Four Per Fixture.)
DF-22-W=Drywall Frame Kit
(Order Individually as Accessory.)
REP=Riveted Endplates, for use in
NewYork City.
ST=Semi-SpecularTannenbaum
Main Reflector
LSC=Lamp Shield Cable
Packa g i n g
U
=Unit Pack
PALC=Job Pack,
in carton
BallastTy p e
( 2)
E B T =T5 Linear Electronic Program Rapid
S t a rtTotal Harmonic Distortion < 10 %
D L S=Digital Lighting System Dimming
No. of Ballast
1,2 or 3
NOTES:
Products also available in non-US voltages and
frequencies for international markets.
(2)
EQ  = T-BAR Safety Earthquake Clips 
    (Use Four Per Fixture) 
DF-22-W = Drywall Frame Kit 
Catalog No.
Wt.
2RDI-114T5RPD
17 lbs.
2RDI-214T5RPD
17 lbs.
2RDI-314T5RPD
17 lbs.