Lightolier WES SERIES 1X4 Prospecto

Descargar
Página de 2
CLEANGUARD WET LOCATION
WES SERIES 1X4
Page 2 of 2
1' x 4' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE
1 OR 2 LAMPS, T8 OR T12 
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 6/Folio N30-10
Job Information
Type:
OPTIONS & ACCESSORIES
SPECIAL LENSES: Substitute VI for VA (standard) .125" nominal pattern 12
with 6.8 oz. average weight per square foot.
ACCESS PLATE: Top wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify
separately. Order Catalog Number: ACP CSP.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges
are required between fixtures. Order Catalog Number: 1FC TRIM (each joint).
PLASTER FRAMES: F type fixtures do not include plaster frames. For individ-
ual or continuous mounting, specify PF14 universal frame per fixture.
ELECTRICAL/WIRING OPTIONS: Consult factory.
SEISMIC HOLD-DOWN CLIP: For type G troffers. SUFFIX: 2HD.
FUSING:
Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture
is standard. SUFFIX: RF.
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .68. To prevent glare the VCP shall not be less than 46 either length-
wise or crosswise (at 100fc level) and the average brightness at 65° shall not
exceed 682 footlamberts. To control veiling reflections, luminaire output in the
30°-90° zone shall not be less than 66.4%.
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing is contoured for rigidity with all edges turned up for safe handling. Lens
frame
—(FS) flat full-size steel frame, (FA) flat full-size extruded 
aluminum frame, (RA) regressed full-size extruded aluminum frame.
FINISH: Chassis exterior—black baked polyester enamel. Cavity—white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones,
running 45° to the panel edge, .095" nominal thickness (similar to pattern 12).
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY
MODEL NO. WES1GFSVA232
ORDERING INFORMATION
Explanation of Catalog Number.   Example: WES1GFSVA232120SOGLR
WE
CLEANGUARD
WET
LOCATION
S
STATIC
1
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and
plaster frame
LENS FRAME:
FS= Flat steel
frame
FA=Flat aluminum
frame
RA=Regressed alu-
minum frame
LENS/
SHIELDING
TYPE:
VA=Virgin acrylic
(standard), see
options and
consult factory
LAMP
QUANTITY:
1 or 2 Lamps
LAMP/
FIXTURE LENGTH:
32=T8
34=T12
(Nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
2 Lamp Mag. T12
LE
<20THD <10THD
2 Lamp Elec. T8
SO*
H
I
*
LOL T8 Dimming
PS
*Instant Start Standard
OPTIONS:
Add appropriate
suffix to catalog
no., ie: (GLR)
coefficients of utilization — zonal cavity method
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
71
68
66
64
62
61
61
60
59
2
65
61
57
57
55
52
55
53
51
3
60
55
50
52
48
45
50
47
45
4
56
49
44
47
43
40
45
42
39
5
51
44
39
42
38
35
41
37
34
6
48
40
35
38
34
31
37
33
30
7
44
36
31
35
30
27
34
30
27
8
41
32
27
31
27
24
30
26
23
9
37
29
24
28
24
21
27
23
20
10
35
27
22
26
21
18
25
21
18
visual comfort probability 
(VCP) average 100 fc; reflectances 80/50/20
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
60
64
70
77
61
65
70
76
20
30
51
56
61
67
54
57
62
68
20
40
47
50
55
60
51
53
57
61
20
60
43
46
59
54
49
50
52
56
30
20
62
66
70
75
63
67
70
75
30
30
53
57
61
65
55
58
62
66
30
40
48
51
54
58
51
53
56
60
30
60
44
46
48
52
49
50
51
54
30
80
42
44
44
48
48
49
49
51
40
20
64
68
72
75
64
68
72
75
40
30
55
59
63
66
57
60
63
66
40
40
49
52
55
59
53
54
57
60
40
60
45
47
49
52
50
51
51
54
40
80
43
45
45
48
49
50
49
50
40
100
42
43
43
45
50
49
48
49
60
30
57
60
64
67
58
61
64
67
60
40
51
53
56
60
54
55
57
60
60
60
46
48
49
52
50
51
51
54
60
80
44
45
45
48
49
50
49
50
60
100
43
43
42
45
50
49
47
48
100
40
55
57
59
62
57
58
59
63
100
60
50
51
52
55
53
54
53
56
100
80
47
48
47
50
52
52
50
52
100
100
46
46
44
46
52
51
49
49
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FL - 48.3
IW - 80.0
BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $5.00
Other dimming options. Consult factory.