Lightolier CFH1GPF Prospecto

Descargar
Página de 2
Ordering Information
Explanation of Catalog Number. Example: CFH1GPF232120SOGLR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK91X4 and CF4FK SPACER.
Electrical Wiring Options: Consult factory.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .55. To reduce glare the average brightness at 65° shall not exceed
2454 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 70.4%. 
Materials: Chassis parts are die-formed 20 gauge steel.
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic
overlay.
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Reflector – baked flat white acrylic enamel, minimum
86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white
acrylic enamel.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
CF
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Coffaire:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
Body Style:
= Air Return
= Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp
Shield
Lamp:
(By Others)
32 = T8
28 = T5
54 = T5HO
(Nominal 48")
F
White 
Reflector
Lamp
Quantity
= 1 Lamp
= 2 Lamp
Ballast Type:
<
20THD
<
10THD
1 & 2 Lamp Elec. T8
SO*
H
*
1-2 Lamp 28W Elec. T5
P
1-2 Lamp 28W Elec. T5
† 
PG ††
1-2 Lamp 54W Elec. T5
† 
PG ††
Linear T5 Instant Start
WA
less than 10THD,
57.5 Input Watts,
0.93 Ballast Factor
LOL Dimming T8
PS
*Instant Start Standard
†Instant Start (120V or 277V only)
††Program Rapid Start (UNV only)
Other dimming options. Consult factory.
NOTE: 
For T8 UNV, you must use H
Ballast Code.
CN
For Local 3
Manufacturing
For Local 3 Manufacturing, substitute
for
. Example: CNH1GPF232120SOGLR.
.
CN
CF
0.0
45.0
90.0
FLUX
0
1157
1157
1157
5
1147
1148
1153
109
15
1096
1095
1100
309
25
1004
998
995
460
35
877
858
854
539
45
720
692
696
540
55
535
514
511
464
65
343
330
341
333
75
172
168
165
175
85
27
33
34
39
90
0
0
0
Coffaire Recessed Fluorescent
CFH1GPF
Page 2 of 2
Direct/Indirect – 1' x 4' with New Perforated Basket
Air Return/Static, 1 Lamp or 2 Lamp T8 or T5
Model No. CFH1GPF232120SO
LER = FP - 38.0
IW - 67.7
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $6.32
Report Number: G2004063
Catalog Number: CFH1GPF232120SO
Lamps: F32/T8  TL841
Luminaire: CFH 1' x 4' with perforated 
basket
Ballast: Triad B332I120
Report is based on 2850 Lumens per lamp.
Efficiency: 52.1%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.2
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.920
10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
3079.
2959.
2977.
55
2821.
2710.
2694.
65
2454.
2361.
2440.
75
2010.
1963.
1928.
85
0
937.
1145.
1180.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 57 55 52 51 50 48 49 48 47
0
2 52 48 44 45 42 40 43 41 39
0
3 47 42 38 40 36 34 38 36 33
0
4 44 37 33 35 32 29 34 31 29
0
5 40 34 29 32 28 25 31 27 25
0
6 37 30 26 29 25 22 28 25 22
0
7 34 27 23 26 22 20 26 22 19
0
8 32 25 21 24 20 18 23 20 17
0
9 30 23 19 22 18 16 22 18 16
10 28 21 17 21 17 14 20 17 14
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
0
879
15.4
29.6
0
0-
0
40
1418
24.9
47.8
0
0-
0
60
2421
42.5
81.6
0
0-
0
90
2968
52.1
100.0
90-180
000
0
0.0
00
0.0
0
0-180
2968
52.1
100.0
ZONAL LUMEN SUMMARY
Job Information
Type:
Lightolier 
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
Section 5/Folio M15-20
Voltage:
120, 277 or
UNV=120-277
0.0
45.0
90.0
FLUX
0
1076
1076
1076
5
1065
1069
1075
102
15
1018
1025
1031
289
25
935
939
944
433
35
820
819
834
516
45
677
680
699
528
55
510
523
513
460
65
333
335
346
336
75
173
178
179
185
85
31
44
46
49
90
0
0
0
Model No. CFH1GPF228120WA
LER = FP - 47.5
IW - 57
BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $5.05
Report Number: G2005196
Catalog Number: CFH1GPF228120WA
Lamps: FP28/835/PM ECO
Luminaire: CFH 1' x 4' with perforated 
basket
Ballast: WA Energy Saver System
Report is based on 2600 Lumens per lamp.
Efficiency: 55.7%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.2
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.920
10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
2895.
2908.
2989.
55
2689.
2757.
2705.
65
2383.
2397.
2476.
75
2021.
2080.
2091.
85
0
1076.
1527.
1596.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 61 58 56 54 53 51 52 51 50
0
2 55 51 47 48 45 42 46 44 41
0
3 50 45 40 42 39 36 41 38 35
0
4 46 40 35 37 34 30 36 33 30
0
5 43 35 30 34 30 26 33 29 26
0
6 39 32 27 30 26 23 29 26 23
0
7 36 29 24 28 24 21 27 23 20
0
8 34 25 22 25 21 18 25 21 18
0
9 32 24 20 23 19 17 23 19 16
10 30 22 18 22 18 15 21 17 15
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
0
824
15.9
28.4
0
0-
0
40
1340
25.8
46.2
0
0-
0
60
2328
44.8
80.3
0
0-
0
90
2898
55.7
100.0
90-180
000
0
0.0
00
0.0
0
0-180
2898
55.7
100.0
ZONAL LUMEN SUMMARY