Cooper Lighting VT3-332 Prospecto

Descargar
Página de 2
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
10/06/2008 11:40:01 AM
Specifications and Dimensions subject to change without notice.
ADF071376
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
VT3
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
VT3-232DR-UNV-
EB81-WL-U
(1) Electronic Ballasts
(2) 32W T8 lamps
2850 lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 77.4%
Test Report:
LTL10864.IES
LER =FL72
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.34
1103 
1103 
1103
1097 
1108 
1107
1083 
1107 
1106
1059 
1091 
1127
1025 
1089 
1113
983 
1058 
1098
932 
1035 
1088
870 
991 
1052
801 
952 
1024
725 
892 
971
640 
831 
920
548 
753 
878
451 
683 
814
352 
611 
771
251 
550 
698
155 
471 
592
77 
367 
513
28 
290 
427
217 
342
91  91  91  91 
89  89  89  89 
84  84  84 
79  79  79 
75  75  75 
73
82  78  74  70 
79  75  72  69 
71  68  66 
67  65  63 
64  62  60 
58
74  67  61  56 
71  65  60  55 
61  57  53 
58  54  51 
55  52  49 
47
67  58  52  46 
65  57  51  46 
54  49  44 
51  47  43 
49  45  42 
40
61  51  44  39 
59  50  43  38 
48  42  37 
45  40  36 
43  39  35 
33
56  45  38  32 
54  44  37  32 
42  36  31 
40  34  30 
38  33  30 
28
51  40  33  28 
49  39  32  27 
37  31  27 
36  30  26 
34  29  26 
24
47  36  29  24 
45  35  28  23 
33  27  23 
32  27  23 
30  26  22 
20
43  32  25  20 
42  31  25  20 
30  24  20 
29  23  19 
27  23  19 
17
40  29  22  17 
38  28  22  17 
27  21  17 
26  20 17 
25  20  16 
15
37  26  20  15 
36  26 19  15 
24  19  15 
23  18  15 
22  18  14 
13
899
15.8
20.4
1512
26.5
34.3
2847
49.9
64.5
4169
73.1
94.5
4413
77.4
100.0
L u m i n a n c e   Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
5519
7213
7212
55
5083
6756
7098
65
4347
6377
7074
75
3001
6097
6510
85
1349
5151
6092
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
L u m i n a n c e   Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
7704
10245
10279
55
7142
9700
9531
65
6126
8631
10102
75
4240
9114
10293
85
2265
7674
8760
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
VT3-254T5DR-UNV-
EHT1-WL-U
(1) Electronic Ballasts
(2) 54W T5 lamps
4400 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.5 x
mounting height
Efficiency 69.7%
Test Report:
LTL10777.IES
LER =FL59
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $4.05
1546 
1546 
1546
1540 
1525 
1533
1519 
1548 
1525
1483 
1514 
1546
1436 
1509 
1566
1375 
1487 
1530
1300 
1446 
1509
1215 
1396 
1502
1118 
1315 
1425
1012 
1267 
1384
896 
1174 
1308
770 
1081 
1179
634 
954 
1107
496 
827
1101
352 
771 
1044
219 
704 
936
113 
578 
807
47 
432 
614
13 
285 
431
82  82  82  82 
80  80  80  80 
76  76  76 
72  72  72 
69  69  69 
67
74  70  66  63 
72  68  65  62 
65  62  59 
61  59  57 
58  57  55 
53
66  60  55  50 
64  58  54  49 
55  51  48 
53  49  46 
50  47  45 
43
60  52  46  41 
58  51  45  41 
49  44  40 
46  42  39 
44  41  38 
36
55  46  40  35 
53  45  39  34 
43  38  33 
41  36  33 
39  35  32 
30
50  40  34  29 
48  40  33  29 
38  32  28 
36  31  27 
34  30  27 
25
46  36  29  25 
44  35  29  24 
34  28  24 
32  27  24 
31  26  23 
22
42  32  26  21 
41  32  25  21 
30  25  21 
29  24  20 
28  23  20 
18
39  29  23  18 
38  28  22  18 
27  22  18 
26  21  17 
25  20  17 
16
36  26  20  16 
35 25  19  15 
24  19  15 
23  18  15 
22  18  15 
13
33  23  18  14 
32  23  17  14 
22  17  13 
21  17  13 
20  16  13 
12
1253
14.2
20.4
2112
24.0
34.4
3985
45.3
64.9
5908
67.1
96.3
6137
69.7
100.0
S A M P L E   N U M B E R :  V T 3 - 2 3 2 D R - U N V- E B 8 1- W L- U
Tandem
Blank
= 4' Length 
8T=8' Length
Series
VT3=Vaportite
Number of Lamps
(3)
1, 2 or Lamps
(Not included)
Wattage (Length)
32
=32W T8 (48") 
28T5=28W T5 (48") 
54T5=54W T5HO (48")
(5)
Lens
DR
=Internal Prismatic Lens/15% DR High Impact Additive (Standard)
DR-50=50% High Impact Additive (High Impact)
DR-100=100% High Impact Additive (Extreme)
Voltage
(1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120/277
(2)
UNC=Universal
Voltage 347/480
WL=Wet Label
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed
(3), (4)
Options
8L
=8 Latches (IP67 Rating)
M4=Miro 4 Interior Reflector
RIF1=Radio Interference
Suppressor
TH=(2) Top Watertite Hubs
only, no End Hubs
(5)
TEH=(2) Top & (2) End
(5)
Watertite Hubs (all Watertite
Hubs have 1/2" Conduit
Entry)
SSL=Stainless Steel Latches
Packaging
U
=Unit Pack
Ballast Type
(1), (4)
EB8   =T8 Electronic Instant Start. 
Total Harmonic  Distortion < 10%
EB8   /PLUS=T8 Electronic Instant Start. 
High Ballast Factor >1.13. Total 
Harmonic  Distortion < 20%
ER8   =T8 Electronic Program Rapid Start. 
Total Harmonic Distortion < 10%
EBT   = T5 Linear Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EHT   = T5 Linear Electronic Start High Ambient.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
No. of 
Ballast
1 or 2
No. of Ballast
1 or 2
No. of Ballast
1 or 2
No. of Ballast
(3)
1 or 2
NOTES
(1)
Products also available in non-US voltages and frequencies for international
markets. 
(2)
Not available when specifying emergencies, voltage must be specific. 
(3)
3
Lamp 54W T5HO is recommended for ambient temperatures below 102°F (40°C) with
EHT2 ballasts, and below 0°F (-18°C) with EHT1 ballast. 
(4)
Emergency option in 3 lamp
version must use remote mount test switch. 
(5)
Top Hub required when stem mounting.
For complete product data, reference the Fluorescent Specification binder. Specifications &
dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
Accessories (order separately)
VT2-Chain/Set-U=Chain Hanging Set
Includes 6 ft. of chain, 4 large S-Hooks and 4
small S-Hooks
Order One (1) Kit for each 4' Fixture
Two (2) Kits Recommended For 8' Fixtures.
VT2-SS-MBK=Stainless Steel Mounting
Bracket
VT3-132 DR-WL
16 lbs.
VT3-232 DR-WL
16 lbs.
VT3-154T5
16 lbs.
VT3-254T5
16 lbs.
Catalog No.
Wt.