Cooper Lighting P4PE-X/TE Prospecto

Descargar
Página de 2
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
09/02/2008 1:52:21 PM
Specifications and Dimensions subject to change without notice.
ADF041664
PHOTOMETRICS
ORDERING INFORMATION
SHIPPING INFORMATION
2HBG
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l  VC P   Pe r c e n t a g e s
Height Along
Height Across
Room Size (Ft.)
8.5’
10.0’
8.5’
10.0’
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
||
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2HBG-632
(2) Electronic Ballasts
(6) F32T8/TL835
lamps
3000 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 83.4%
Test Report:
2HBG632.IES
LER =81
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.98
4712
4712
4712
4701
4666
4675
4637
4691
4905
4529
4898
5448
4377
5225
5702
4182
5345
5543
3940
5249
4951
3658
4835
4926
3341
4206
3576
2991
3554
3029
2615
2865
2759
2217
2323
2430
1804
1996
2234
1389
1644
2248
990
1495
1993
626
1286
1567
319
832
740
85
172
81
0
0
0
99 99 99 99
97 97 97 97
93 93 93
89 89 89
85 85 85
83
91 87 83 80
88 85 82 79
81 79 76
78 76 74
75 73 72
70
82 76 70 65
80 74 69 64
71 67 63
68 65 61
66 63 60
58
75 66 59 54
73 65 59 54
62 57 53
60 56 52
58 54 51
49
69 59 51 46
67 58 51 45
56 50 45
54 48 44
52 47 44
42
63 53 45 39
62 52 45 39
50 44 39
48 43 38
47 42 38
36
58 47 40 34
57 47 39 34
45 39 34
44 38 34
42 37 33
32
54 43 36 30
53 42 35 30
41 35 30
40 34 30
39 33 30
28
50 39 32 27
49 39 32 27
37 31 27
36 31 27
35 30 27
25
47 36 29 24
46 35 29 24
34 28 24
34 28 24
33 28 24
22
44 33 26 22
43 33 26 22
32 26 22
31 26 22
30 25 22
20
4174
23.2
27.8
6937
38.5
46.2
11814
65.6
78.7
15014
83.4
91.5
15014
83.4
100.0
39
45
30
39
32
36
24
27
31
33
24
23
33
36
28
31
31
31
28
25
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l  VC P   Pe r c e n t a ge s
Height Along
Height Across
Room Size (Ft.)
8.5’
10.0’
8.5’
10.0’
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
||
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2HBG-654T5
(3) Electronic Ballasts
(6) F54T5/841HO
lamps
4400 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.1 x
mounting height
Efficiency 73.5%
Test Report:
2HBG654T5.IES
LER =63
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $3.83
8439 
8439 
8439
8404 
8519 
8622
8289 
8683 
8905
8092 
8740 
8905
7819 
8587 
8396
7473 
8150 
7205
7048 
7258 
5694
6550 
6095 
4381
5978 
4755 
3520
5335 
3616 
3031
4640 
2835 
2535
3909 
2324 
2239
3157 
1829 
2296
2411 
1567 
2296
1692 
1536 
1764
1042 
1167 
1297
500 
669 
602
100 
135 
22
0
37
41
33
41
32
34
28
30
31
31
29
27
35
36
32
34
33
32
33
29
6821
25.8
35.1
10503
39.8
54.1
16195
61.3
83.4
19412
73.5
100.0
19412
73.5
100.0
88  88  88 88 
86  86  86  86 
82  82  82 
78  78  78 
75  75  75 
74
81  78  75 72 
79  76  73  71 
73  71  69 
70  68  67 
67  66  65 
63
74  68  64 60 
72  67  63  59 
65  61  58 
62  59  57 
60  58  55 
54
68  61  55 51 
66  60  55  50 
58  53  50 
56  52  49 
54  51  48 
46
63  55  48 44 
61  54  48  44 
52  47  43 
50  46  42 
49  45  42 
40
58  49  43 38 
57  48  43  38 
47  42  38 
45  41  37 
44  40  37 
36
54  45  38 34 
53  44  38  34 
43  37  34 
41  37  33 
40  36  33 
32
50  41  35 30 
49  40  34  30 
39  34  30 
38  33  30 
37  33  30 
28
47  37  32 27 
46  37  31  27 
36  31  27 
35  30  27 
34  30  27 
26
44  35  29 25 
43  34  29  25 
33  28  25 
33  28  25 
32  28  25 
23
41  32  27 23 
40  32  26  23 
31  26 23 
30  26  23 
30  26  23 
21 
S A M P L E   N U M B E R :   2 H B G - 6 5 4 T 5 - A- U N V- E B T 2 - U
Ballast Type
ER8   
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB8   =T8 Electronic Instant Start. 
Total Harmonic Distortion < 10%
EB8   /PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total 
Harmonic Distortion < 20%
EBT   =T5 Linear Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of 
Ballast
1, 2 or 3
No. of Ballast
1 or 2
NOTES:
(1)
Voltage must be specified when ordered with plugs, motion or emergency ballasts.
No. of Lamps
4=4 Lamps
6=6 Lamps
Lamp Type
32=32W T8 Lamps (48")
28T5=28W T5 Lamps (48")
54T5=T5HO Lamps (48")
Series
HB=High Bay
Width
2=24"
Voltage
(1)
UNV=Universal
120/277 Voltage
UNC=Universal 347/480
Voltage (T5 linear only)
120V=120 Volt
277V=277 Volt
347V=347 Volt
Downlight Optic
Blank=Open
A=Prismatic Acrylic Lens & Aluminum Doorframe
CL=Clear Acrylic Lens & Aluminum Doorframe
Distribution Optic
Blank=Medium (Specular Aluminum)
G=Wide (White Painted)
Trim Type
G=Grid/Lay-in (Standard)
F=Flange Trim
Options
C3=3' Power Cord
C6=6' Power Cord
PC3-=3' Power Cord & Plug
(Specify Voltage)
(1)
PC6-=6' Power Cord & Plug
(Specify Voltage)
(1)
Packaging
U
=Unit Pack
PAL=Job Pack, out of carton
PALC=Job Pack, in carton
Options
Lamps Installed
L8830=T8 Lamp, 80CRI 3000K
L8835=T8 Lamp, 80CRI 3500K
L8841=T8 Lamp, 80CRI 4100K
L8850=T8 Lamp, 80CRI 5000K
L5830=T5 Lamp, 80CRI 3000K
L5835=T5 Lamp, 80CRI 3500K
L5841=T5 Lamp, 80CRI 4100K
L5850=T5 Lamp, 80CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
Emergency=EM Installed
(1)
Accessories (order separately)
MWS=Modular Wiring System
2HBG-632
42 lbs. 
2HBG-654
42 lbs.
Catalog No.
Wt.