PHOTOMETRICS
SHIPPING INFORMATION
ORDERING INFORMATION
HBO
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
L u m i n a n c e   Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
11108
10361
9732
55
11229
9310
5591
65
11258
4950
3894
75
10611
3726
3407
85
6828
3934
3418
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3HBO-654T5-G-UPL
(2) Electronic Ballasts
(6) 54W T5 lamps
4500 lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 84.5%
Test Report: 18450
8100 
8100 
8100
8068 
8072 
8068
7983 
7974 
7954
7836 
7799 
7799
7639 
7585 
7561
7381 
7303 
7250
7066 
6943 
6870
6710 
6522 
6412
6293 
6019 
5777
5843 
5450 
5120
5327 
4734 
3794
4791 
3973 
2386
4195 
2747 
1630
3539 
1556 
1224
2842 
1066 
910
2043
717 
656
1213 
461 
464
443 
255 
222
40 
45 
27
99  99  99  99 
96  96  96  96 
91  91  91 
86  86 86
81  81  81 
79
91 88 84  81 
88  85  82  79 
81 78  76 
76  74  73 
72  71  69 
67
83  77  72  67 
81  75  70  66 
71  67  63 
67  64  61 
64  61  59 
57
76  68  62  56 
74  66  60  55 
63  58  54 
60  56  52 
57  54  51 
49
70  61  53  48 
68  59  52 47
56  51  46 
54  49  45 
51  47  44 
42
65  54  47  42 
62  53  46  41 
51  45  40 
48  43  39 
46  42  38 
36
60  49  42  36 
58  48  41  36 
46  40  35 
44  39  35 
42  37  34 
32
55  44  37  32 
54  43  37  32 
42  36  31 
40  35  31 
38  34  30 
28
52  40  34  29 
50  40  33  28 
38  32  28 
37  31  27 
35  31  27 
25
48  37  30  26 
47  36  30  26 
35  29  25 
34  29  25 
33  28  24 
23
45  34  28  23 
44  34  27  23 
32  27  23 
31  26  23 
30  26  22 
21
6338
23.5
27.8
10422
38.6
45.7
17906
66.3
78.5
21315
78.9
93.4
22821
84.5
100.0
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
L u m i n a n c e   Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
16940
9242
5650
55
15744
5131
1412
65
13730
602
158
75
10356
258
304
85
4571
714
714
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3HBO-654T5-UPL
(2) Electronic Ballasts
(6) 54W T5 lamps
4500 lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.1 x
mounting height
Efficiency 91.7%
Test Report: 18451
13864 
13864 
13864
13828 
13980 
14046
13628 
13685 
13227
13309 
12830 
12699
12859 
12269 
11308
12282 
11197 
9599
11599 
9618 
7544
10796 
8039 
6051
9900 
6157 
4211
8911 
4862 
2972
7840 
3229 
1834
6718 
2189 
602
5541 
1147 
74
4317 
189 
50
3123 
50 
51
1994 
50 
59
1020 
50 
51
296 
46 
46
27 
21 
21
108 108 108 108 
105 105 105 105 
99  99  99 
94  94  94 
89  89  89 
87
101 98  95  92 
98  95  92  90 
91  88  86 
86  85  83 
82  81  80 
78
94  88  83  79 
91  86  81  78 
82  78  75 
78  75  73 
75  73  71 
69
87  79  73  68 
85  78  72  68 
74  70  66 
71  67  64 
69  65  63 
61
81  72  65  60 
79  70  64  59 
68  62  58 
65  61  57 
63  59  56 
54
75  65  58  53 
73  64  58  53 
62  56  52 
60  55  51 
58  53  50 
48
70  60  53  48 
68  59  52  47 
57  51  47 
55  50  46 
53  49  45 
43
66  55  48  43 
64  54  47  43 
52  46  42 
51  45 42 
49  44  41 
39
61  51  44  39 
60  50  43  39 
48  42  38 
47  42  38 
46  41  37 
36
58  47  40  36 
56  46  40  35 
45  39  35 
44  38  35 
42  38  34 
33
54  44  37  33 
53  43  37  33 
42  36  32 
41  36  32 
40  35  32 
30
10007
37.1
40.4
15138
56.1
61.1
21858
81.0
88.3
23497
87.0
94.9
24766
91.7
100.0
3HBO-854T5-120V-UPL
27 lbs.
Catalog No.
Wt.
S A M P L E   N U M B E R :   3 H B OT- 8 5 4 T 5 - U N V- E B T 2 - U P L- U
No. of Lamps
8=8 Lamps
Lamp Type
54T5=54W T5HO (4') Lamp
Series
HBO=High Bay Open
Body
HBOT=High Bay Open
Top Version
Width
3=32" wide
Voltage
(2)
UNV=Universal
120/277 Voltage
UNC=Universal
347/480 Voltage
(T5 linear only)
(6)
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Distribution
Blank=Medium (Specular Aluminum)
G=Wide (White Painted)
Options
MWS=Modular Wiring System
MS=Aisle Coverage Motion 
Sensor
(4)
MSO=360˚ Coverage Motion 
Sensor
(4)
MP=Modular Power 
Receptacle
(1) (2)
PC3-=3' Power Cord & Plug (Specify Voltage)
(2)
PC6-=6' Power Cord & Plug (Specify Voltage)
(2)
TCBP=Top Connector Box Plate
(5)
Packaging
U
=Unit Pack
PAL=Palletized
Out of Carton
PALC=Palletized
In Carton
Options
L5830=T5 Lamp, 85CRI 3000K
L5835=T5 Lamp, 85CRI 3500K
L5841=T5 Lamp, 85CRI 4100K
L5850=T5 Lamp, 85CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
Emergency=Emergency Installed
(2)
Ballast Type
T5 Systems
EBT   
=T5 Linear Electronic Program Rapid Start 
(3)
Total Harmonic Distortion < 10%
EHT   =T5 Electronic Program Start High Ambient
(6)
Total Harmonic Distortion < 10%
DIM=Consult Factory
(7)
No. of Ballast
2, 3 or 4
No. of Ballast
2, 3 or 4
Accessories (order separately)
Mounting
AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets
w/S-Hooks
(8)
TCB=Top Connector Box
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
MPC6=6' Modular Power Cord & Plug (Specify
Voltage)
MC6=6' Modular Power Cord
MMS-CPD1200H=Aisle Motion Sensor, Box,
Modular Power Receptacle (120-277V)
MMS-CPD500H=360° Motion Sensor, Box,
Modular Power Receptacle (120/277V)
NOTES:
(1)
Requires use of MC   or MPC  cord accessories, specify voltage for plugs. 
(2)
Voltage must be specified when ordered with plugs, motion or
emergency ballasts. 
(3)
EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C). 
(4)
Specify voltage on ballast. 
(5)
For use
with Top Connector Box options. See accessories. 
(6)
2 lamp ballast configurations only in EHT-UNC versions. 
(7)
Dimming ballast must be specified at
time of order.