Cooper Lighting HBOT T8 SERIES Prospecto

Descargar
Página de 2
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
07/01/2008 11:14:52 AM
Specifications and Dimensions subject to change without notice.
ADF060954
PHOTOMETRICS
SHIPPING INFORMATION
ORDERING INFORMATION
HBOT
C o e ffi c i e n t s   o f   U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Z o n a l   L u m e n   S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle
Along II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
3HBOT-832-UPL
(2) Electronic Ballasts
(8) 32W T8 lamps
3000 lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.3 x
mounting height
Efficiency 89.8%
Test Report: 18445
LER =84
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $2.84
9244 
9244 
9244
9215 
9146 
9136
9092 
8966 
8971
8882 
8776 
8995
8595 
8674 
8786
8228 
8404 
8223
7779 
7876 
7417
7261 
7129 
6852
6670 
6294 
5874
6025 
5639 
4647
5311 
4603 
3196
4574 
3427 
1921
3783 
2141 
954
3000 
1061 
309
2204 
378 
30
1442
46 
13
765 
18 
1
250 
30 
21
13 
1
106 106 106 106 
103 103 103 103 
98 98 98
93 93  93 
88  88  88 
86
99  95  92  89 
96  93  90  87 
88  86  84 
84  83  81 
81  79  78 
76
91  85  80  75 
88  83  78  74 
79  75  72 
76  73  70 
73  70  68 
66
84  76 69 64 
81  74  68  63 
71  66  62 
68  64  60 
65  62  59 
57
77  68  61  56 
75  66 60  55 
64  58  54 
61  57  53 
59  55  52 
50
72  61  54  49 
70  60  53  48 
58  52  47 
56  51  46 
54  49  46 
44
66  55  48  43 
64  54  48  43 
52  46  42 
51  45  41 
49  44  41 
39
62  50  43  38 
60  50  43  38 
48  42  37 
46  41  37 
45  40  36 
35
58  46  39  34 
56  45  39  34 
44  38  34 
43 37  33 
41  37  33 
31
54  43  36  31 
52  42  35  31 
41  35  30 
39  34  30 
38  33  30 
28
50  39  33  28 
49  39  32  28 
38  32  28 
37  31  27 
36  31  27 
26
7164
29.8
33.2
11585
48.3
53.8
18756
78.2
87.0
20692
86.2
96.0
21549
89.8
100.0
L u m i n a n c e   Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
8579
8030
6617
55
8029
6016
3372
65
7148
2527
735
75
5611
178
49
85
2887
344
237
Cooper Lighting’s F-Bay Modular Power Supply option allows external
fixture access for safe and easy servicing. There is no need to
remove lamps or reflectors to disconnect fixture power with F-Bay
Modular Power Supply. Access to the individual fixtures power supply
allows servicing without turning off all the fixtures disrupting 
occupants. F-Bay Modular Power Supply is a time saver in installation
– simply plug & power.
1
2
Modular F-Bay Power Supply
1. Modular Power Supply Receptacle supplied 
mounted into fixture Access Plate.
2. Modular Power Cord & Plugs in 120, 277, 347,
& 480V configurations for easy plug & power
into existing supply.
No internal fixture
access required for
installation or 
disconnecting power.
Code Compliance
• UL/cUL Certified for Make/Break 
under load (UL2549)
• Meets NEC requirements for 
ballast disconnect (NEC 410.73G)
• Allows for addition of Occupancy
Sensor without hard connections
• Receptacles complete with 
insulating dustcap
Modular Motion Sensor Option 
supplied with Mounting Box and
Modular Power Supply Receptacle.
3HBOT-832-G-120V-UPL
27 lbs. 
.
t
W
.
o
N
 
g
o
l
a
t
a
C
S A M P L E   N U M B E R :   3 H B OT- 8 3 2 - U N V- E B 8 2 / P L U S - U P L- U
No. of Lamps
8=8 Lamps
Lamp Type
32=32W T8 (4') Lamp 
Series
HBOT=High Bay Open
Top Version
Width
3=32" wide
Voltage
(2)
UNV=Universal
120/277 Voltage
UNC=Universal
347/480 Voltage
(T5 linear only)
(6)
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Distribution
Blank=Medium (Specular Aluminum)
G=Wide (White Painted)
Options
UPL=Uplight Apertures
MWS=Modular Wiring System
MS=Aisle Coverage Motion 
Sensor
(4)
MSO=360° Coverage Motion 
Sensor
(4)
MP=Modular Power Receptacle
(1) (2)
PC3-=3' Power Cord & Plug (Specify Voltage)
(2)
PC6-=6' Power Cord & Plug (Specify Voltage)
(2)
TCBP=Top Connector Box Plate
(5)
Packaging
U
=Unit Pack
PAL=Palletized
Out of Carton
PALC=Palletized
In Carton
Options
Lamps Installed
L8830=T8 Lamp, 85CRI 3000K
L8835=T8 Lamp, 85CRI 3500K
L8841=T8 Lamp, 85CRI 4100K
L8850=T8 Lamp, 85CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed
(2)
Ballast Type
T8 Systems
EB8   
=T8 Electronic Instant Start.
(7)
Total Harmonic Distortion < 10%
EB8   /PLUS=T8 Electronic Instant Start.
(7)
High Ballast Factor >1.15. 
Total Harmonic Distortion < 10%
ER8   =T8 Electronic Program Rapid Start.
(7)
Total Harmonic Distortion < 10%
ER8   /PLUS=T8 Electronic Program Start.
(7)
High Ballast Factor >1.15. 
Total Harmonic Distortion < 10%
No. of Ballast
2 or 3
No. of 
Ballast
2 or 3
No. of Ballast
2 or 3
NOTES:
(1)
Requires use of MC   or MPC  cord accessories, specify voltage for plugs. 
(2)
Voltage must be specified when ordered with plugs, motion or emergency
ballasts. 
(4)
Specify voltage on ballast. 
(5)
For use with Top Connector Box options. See accessories. 
(6)
2 lamp ballast configurations only in EHT-UNC versions.
(7)
ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration.
Accessories (order separately)
AYC-CHAIN/SET/U=(2) Hooks, 36" Chain
Sets w/S-Hooks
TCB=Top Connector Box
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
MPC6=6' Modular Power Cord & Plug
(Specify Voltage)
MC6=6' Modular Power Cord
MMS-CPD1200H=Aisle Motion Sensor,
Box, Modular Power Receptacle (120/277V)
MMS-CPD500H=360° Motion Sensor, Box,
Modular Power Receptacle (120/277V)
No. of 
Ballast