     access to bolts from side of fixture.
2.
  Using 1/4-20 x1" screws, secure mounting brackets to bottom 
  Brackets can be attached as shown or reversed allowing 
     of ballast enclosure.  
1.
Insert driver through 
mounting holes in bracket
to secure brackets to ballast
enclosure. 
Visor and Non-Visor
Sheet 1 of 3
performed by a certified electrician.  
2.
Warning
:  Before starting any work ensure 
that all sources of power are turned off.  All 
work must meet local/national codes and be 
 
mount fixtures vertically. 
Installation Instructions
1.
Do not
Roundel, XL 
IN/OUTDOOR
BI 
(Base, Integral)
ADY080863 REV A(ECN080377)
Pre-installed
(x4)
1/4-20 bolts
1/4-20 nut
(x4)
1.  After securing mounting brackets to ballast enclosure, slide 
     brackets over pre-installed 1/4-20 bolts in mounting 
     surface.(Refer to page 3 for mounting dimensions)
2.  Using appropriate nuts, secure ballast enclosure to surface.
   
(x10)
1/4-20 x1"
Fixture door
screws
Exploded View and Part Call-Out
enclosure
Captive door
Aiming screw
(4x)
Securing Mounting Brackets
(2x)
(x12)
Integral ballast 
Screw
cover plate
#10-32 x 1/2"
brackets (2x)
End cap
Pan head screws
Hex End bolt
Mounting 
Ballast enclosure 
(2x)
3/8-16 x1"
1/4-20 x1"
1/4-20 x1"
Screw
(4x)
Securing Ballast Enclosure to Surface