Panasonic 1740 Prospecto

Descargar
Página de 2
 
 
 
Panasonic Electric Works Fire & Security Technology Europe AB 
 
Citadellsvägen 23, SE-211 18 Malmö, Sweden 
Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 
info@mfstech.com • www.panasonic-fire-security.com 
 
Fire alarm systems 
Alert annunciation 
controller 1740 
•  Controller for the Alert Annunciation function 
•  Compact size 
Alert annunciation controller 
When the Alert Annunciation (AA) function 
shall be used in system EBL500.  The unit is 
required for the related manoeuvres, i.e. to 
acknowledge / reset the alarms.    
For a detailed description of the Alert 
Annunciation function, see system EBL500 
Planning and Operating Instructions. 
 
The unit shall be mounted close to the c.i.e. 
(or an ext. FBP / Presentation unit) where 
the fire alarms will be presented. 
LEDs, push buttons etc. 
The designation texts for the LEDs and push 
buttons on the front are in Swedish.   
The unit has the following LEDs: 
•  Larm, indicating fire / AA alarm. 
•  Drift, indicating that the unit is in 
operation, i.e. the AA function is 
enabled in the system.  Normally a time 
channel is used to enable this function. 
•  Räddningstjänsten larmad, indicating 
that the "Fire brigade tx" output is 
activated in the c.i.e. because: 
 
-  the activated fire alarm is not an AA 
alarm 
-    the  AA function has been ended, e.g. 
the acknowledge or investigation time 
has run out, etc. 
•  Kvittering, indicating that the AA alarm 
has been acknowledged.   
The unit has the following push buttons: 
•  Kvittering, used to acknowledge an AA 
alarm.  
•  Återställning, used to reset an AA 
alarm. 
Compact size 
The compact size enclosure is made of grey 
high impact ABS.  Fitted with a supple-
mentary "O" ring gasket, it will comply with 
IP61, in respect of dust and moisture.  The 
unit has no door, i.e. the front is accessed 
directly, when required.  The push buttons 
are disabled until they are supposed to be 
used.  The unit shall be wall mounted.   
Miscellaneous 
The LED "Kvittering" (Acknowledge) can 
be turned on by the push button 
"Kvittering" (Acknowledge) or by an 
input, i.e. a programmable output in the 
c.i.e.  This is set via a jumper "JP1" in the 
unit. 
The unit is power supplied from the c.i.e. 
or an external power supply. 
One supplementary compression gland 
can be used for cable entry when required. 
Product application 
1740 is intended to be used in the fire alarm 
system EBL500 but can be used in the 
systems EBL1000 / 2000 / 512 / 128 as well.   
The 1740 controller is intended to succeed 
the alert annunciation controller 2232.