Maintenance/replacement
ENGLISH - 147
Maintenance
3)  Attach the replacement filter unit optional accessory (Model No.: ET-EMF510) to the 
projector.
z
The air filter unit has no difference between top and bottom, but is two-sided. Match the protrusion position 
of the air filter with the grooves on the projector body.
z
Hook the air filter unit frame at the exhaust port side to the two tabs of the back side of the projector’s air 
filter unit compartment and perform Step 
2) in the reverse order to attach.
• Confirm that the tabs of the air filter unit compartment of the projector body are hooked to the air filter unit 
frame.
Tabs on the projector body
Tabs on the projector body
Protrusion of the air filter unit
Protrusion of the air filter unit
Groove on the projector body
Groove on the projector body
4)  Attach the air filter cover to the projector and use a Phillips screwdriver to tighten 
the air filter cover screw.
z
Perform Step 
1) in the reverse order.
Attention
 
z
When switching on the projector, make sure that the air filter unit is installed. If it is not properly attached, the 
projector will suck in dirt and dust causing a malfunction.
–▶If you use the projector without attaching the air filter unit, the message appears on the projection screen for 
approximately 30 seconds.
Note
 
z
The replacement cycle of the air filter unit varies greatly depending on the usage environment.
Lamp unit
The lamp unit is a consumable component. See “When to replace the lamp unit” (
 page 148) for details about 
the replacement cycle.
Consult your dealer to purchase a replacement lamp unit (Model No.: ET-LAD510 (1 pc), ET-LAD510F (4 
pcs)) or a replacement lamp unit (for portrait mode) (Model No.: ET-LAD510P (1 pc), ET-LAD510PF (4 pcs)).
It is recommended that you request a qualified technician to replace the lamp unit. Consult your dealer.
Attention
 
z
Do not replace the lamp unit when it is hot. (Wait at least one hour after use.)
Checking the lamp unit to be replaced
Check the status of the lamp indicators <LAMP1>/<LAMP2>/<LAMP3>/<LAMP4>.
 
z
The lamp unit corresponding to the lamp indicator that is lit in red is required to be replaced.
Notes on the replacement of the lamp unit
z
A Phillips screwdriver is necessary when replacing the lamp unit.
z
Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object.
Please handle with care.
z
Do not disassemble or modify the lamp unit.
z
When replacing the lamp unit, be sure to hold it by the handle because its surface is pointed and its shape 
is protruded.
z
The lamp may be burst. Replace the lamp unit carefully so that the broken pieces of the lamp glass will not 
scatter. When the projector is mounted on the ceiling, do not make the replacement directly under the lamp 
unit or put your face near it.
z
The lamp contains mercury. When disposing of used lamp units, contact your local authorities or dealer for 
correct methods of disposal.
Attention
 
z
Use only specified lamp units.
 
z
For portrait setting, always use the replacement lamp unit (for portrait mode).
 
z
Do not use the replacement lamp unit (for portrait mode) and the ordinary lamp unit together.
 
z
When using the replacement lamp unit (for portrait mode), always use it with portrait setting.