Panasonic PT-DZ16KD Manual De Usuario
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
Chapter 4 Settings — [PROJECTOR SETUP] menu
96 - ENGLISH
[COOLING CONDITION]
Change the fan control depending on the direction of projection.
Set [COOLING CONDITION] according to the projection direction, but set it to [AUTO] normally. Using the projector with incorrect setting may
Set [COOLING CONDITION] according to the projection direction, but set it to [AUTO] normally. Using the projector with incorrect setting may
shorten the life of the lamp.
:
30°
30°
30°
30°
30°
30°
[VERTICAL UP SETTING]
[FLOOR SETTING]
[CEILING SETTING]
[VERTICAL DOWN SETTING]
Projection direction
1) Press as to select [COOLING CONDITION].
2) Press the <ENTER> button.
2) Press the <ENTER> button.
f
The
[COOLING CONDITION] screen is displayed.
3) Press as to select a cooling condition.
f
When [AUTO] is selected, the cooling conditions of [FLOOR SETTING], [CEILING SETTING], [VERTICAL UP SETTING], and
[VERTICAL DOWN SETTING] are set automatically.
You can check the setting from [COOLING CONDITION] on the
You can check the setting from [COOLING CONDITION] on the
[STATUS] screen.
4) Press the <ENTER> button.
5) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
5) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
[HIGH ALTITUDE MODE]
Set this item to [ON] when using the projector at high altitudes between 1 400 m (4 593') and 2 700 m (8 858') above sea level.
1) Press as to select [HIGH ALTITUDE MODE].
2) Press qw to switch the item.
2) Press qw to switch the item.
[OFF]
When using the projector at a location lower than 1 400 m (4 593') above sea level
[ON]
When using the projector at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea
level)
3) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
f
The speed of the fan increases and the operation sound becomes louder when set to [ON].
f
This item cannot be set when using the optional Smoke cut filter (Model No.: ET-SFR510). (Setting is fixed to [OFF].) Use it at elevations
lower than 1 400 m (4 593') above sea level.
[LAMP SELECT]
Select the lamp to be lit from the four built-in luminous lamps according to the use conditions or purposes.
1) Press as to select [LAMP SELECT].
2) Press qw to switch the item.
2) Press qw to switch the item.
[L1]
Lamp 1 will light.
[L2]
Lamp 2 will light.
[L3]
Lamp 3 will light.
[L4]
Lamp 4 will light.
[L1/L4]
Lamp 1 and 4 will light.
[L2/L3]
Lamp 2 and 3 will light.
[L1/L2/L3]
Lamp 1, 2, and 3 will light.