Sanitaire 880 Series Manual De Usuario

Descargar
Página de 8
6
7. Replace Cup
  and Swing
  Lid Shut
5.  Remove
  Cup
6.  Empty
  Cup
5.  Reach  in,  grasp  the  dust  cup  and  pull  it  out  of  the 
support.
6.  Empty contents in a suitable container. (If desired, the cup 
can be washed in warm water using a mild soap solution.  
Be sure the cup is completely dry before replacing.)
7. Place the cup into the support, swing the lid shut, and fasten 
each latch.
8.  Hook clip to top of bag (refer to item 1).
Quick Kleen® Fan Chamber
(880 Series Only)
NOTE:  Turn off the switch and unplug the electrical 
cord before cleaning.
The clear, removable fan chamber 
cover  provides  easy  inspection, 
cleaning, and maintenance of the 
fan chamber.  Removing the cover 
provides easy access to the motor 
fan.  Grease buildup, dirt, or other 
obstructions, visible through the 
fan  cover,  should  be  removed.  
To clean the fan area, take off the 
chrome bottom plate by releasing 
the two cam locks (see Brush Roll 
Belt, Figure 1 and 2).  Remove the belt from the motor pulley, 
then loosen and remove the screws on either side of the fan 
cover, as indicated by the arrows.  Push the cam locks outward 
against the wheels to lift the cover from the cleaner base.  Dirt 
and obstructions can easily be cleared; however, caked grease 
may need to be scraped from the cover and the cleaner.  If 
the fan does not turn freely, it also should be removed for 
cleaning.  To remove the fan, place a wrench over the motor 
pulley.  Hold the fan blades with one hand and turn the wrench 
counterclockwise.  Remove the motor pulley and lift the fan off 
the motor shaft.  Clean the area and replace the fan over the 
motor shaft.  Tighten the motor pulley snugly clockwise with 
the wrench.  If necessary, replace the fan cover or the gasket 
with replacement parts.
Be sure the gasket is in place.  Reposition the fan cover by 
first placing the exhaust end into place between the large rear 
wheels.  Seat the fan cover firmly.  Next replace the belt and 
bottom plate as the pressure from the bottom plate helps seal 
the fan cover.  Start the two screws by hand to be sure they 
are straight, then tighten.
Order  fan  chamber  cover  replacement  kit  (fan  cover, 
gasket, two screws)  Part No. 52334.
A        B        C           D
F
E
D
TO RE-ASSEMBLE
  7. Slide in new brush strip of same length (rounded end 
first) Fit track on either side of brush strip into brush roll 
slot (F).
 
Replace second brush strip from opposite end of brush 
roll (E).
  8.  Replace shaft
  9.  Align indentation on bearing retainer with brush strip on 
both ends of brush roll (D).
 
(replace shaft washer on sleeve bearing assembly)
  1. Remove rubber end cap cover from one end (A).
  2. Unscrew locknut (B).
  3. Remove end cap (sleeve bearing brush roll assembly 
includes a shaft washer, not pictured) (C).
  4. Remove bearing retainer (D).
  5. Push shaft through opposite end (E).
  6. Pull out worn brush strip with pliers (F).
How To Replace Worn Brush Strips 
(chromed steel brush roll)
CAUTION: Turn  off  the  switch  and  unplug  the 
electrical cord before replacing brush 
strips.
New brush strips are supplied in sets of two, one long and 
one short. To replace, remove bottom plate and belt (see 
How To Change Belt). Then, grasp center of brush roll and 
lift to remove.
Brush Roll
As the brush roll rotates, it sweeps and combs the carpet nap. 
Remove hair and threads from the brush roll so it continues 
brushing the carpet nap. When the bristles of the brush roll no 
longer touch a straight edge held across the bottom plate, the 
brush roll is ineffective because the bristles no longer touch 
the carpet nap. To maintain the most effective cleaning, use a 
new wood brush roll. Replace the brush strips on the chromed 
steel brush roll.