6 AMP CONTROL CIRCUIT CIRCUIT BREAKER
When the Control Circuit Circuit Breaker (15) trips, push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local Nilfisk-Advance Distributor for service.
20 AMP WHEEL DRIVE CIRCUIT BREAKER
When the Wheel Drive Circuit Breaker (15) trips, check to see if there is debris wrapped around the wheel axle.  Remove the debris from the axle.
Have the wheel drive motor checked for worn out brushes; repair or replace the motor if necessary.  Push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local Nilfisk-Advance Distributor for service.
20 AMP BRUSH DRIVE CIRCUIT BREAKER
When the Brush Drive Circuit Breaker (15) trips, check to see if the brush height is set too low or if there is debris wrapped around the brush.
Adjust the brush height or remove the debris from the brush.  Push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local Nilfisk-Advance Distributor for service.
40 AMP VACUUM MOTOR CIRCUIT BREAKER
When the Vacuum Motor Circuit Breaker (15) trips, check the Vac Motor Filters (32) and clean or replace if necessary.  Have the vacuum motors
checked for worn out bearings and/or brushes or bearing failure.  Repair or replace the motors if necessary.  Push the button to reset the circuit
breaker.
If the circuit breaker trips repeatedly, call your local Nilfisk-Advance Distributor for service.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
AquaMAX™ / AX 650
Model No.
56212000 / 56212260
Voltage, batteries
V
36V
Battery capacity
Ah
238
Protection grade
IPX3
Sound power level as per ISO 3744 (at operator)
dB(A)/20µPa
76
Gross weight (with acc. and batteries, full tank)
lbs / kg
1,171 / 531
Vibrations at the Hand Controls
m/s
2
<2,5m/s
2