Nilfisk Alto ATTIX 761-2MXC Manual De Usuario
14
english
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
1)
Option depending on model
Fault
Cause
Remedy
‡ The acoustic warning
sounds. (Reduced suction
power)
power)
> Filter element is clogged.
•
See section 4.5/4.6 „Cleaning
filter element“ and 7.2.5/7.2.6
„Replacing filter element“.
filter element“ and 7.2.5/7.2.6
„Replacing filter element“.
> ATTIX 560-2MXC/761-2MXC
only:
Defective cleaning mecha-
nism
Defective cleaning mecha-
nism
•
Contact Nilfisk-Alto Service
‡ No suction power during
wet cleaning
> Tank is full. (Float does not
close the suction opening).
•
Switch off the cleaner. Empty
the tank.
the tank.
‡ The vacuum cleaner
switches off during wet
cleaning
cleaning
> Tank is full.
•
Switch off the cleaner. Empty
the tank.
the tank.
‡ Voltage fluctuations
> Impedance of power supply is
too high.
•
Connect the cleaner to an-
other socket closer to the fuse
box. Voltage fluctuations over
7% should not occur if the im-
pedance at the transfer point
is
other socket closer to the fuse
box. Voltage fluctuations over
7% should not occur if the im-
pedance at the transfer point
is
≤ 0.15 Ω .
9.2 Guarantee
Our general conditions of busi-
ness are applicable with regard
to the guarantee. Subject to
change as a result of technical
advances.
ness are applicable with regard
to the guarantee. Subject to
change as a result of technical
advances.
9.3
Tests and approvals
The vacuum cleaners have been
tested as specified in IEC/EN
60335-2-69 including appendix
AA. All the requirements were
fulfilled for equipment in dust
class M.
tested as specified in IEC/EN
60335-2-69 including appendix
AA. All the requirements were
fulfilled for equipment in dust
class M.
The vacuum cleaners must be
inspected regularly in accord-
ance with national accident pre-
vention regulations (in Germany
as specified in BGV A2 and DIN
VDE 0701 Part 1 and Part 3, at
regular intervals and after re-
pairs or modifications).
inspected regularly in accord-
ance with national accident pre-
vention regulations (in Germany
as specified in BGV A2 and DIN
VDE 0701 Part 1 and Part 3, at
regular intervals and after re-
pairs or modifications).
A dust test must be performed
at least once every year by the
manufacturer or a trained per-
son. This test covers, for exam-
ple, whether there is damage to
the filter, the vacuum cleaner is
sealed to the air and the control
equipment works properly.
at least once every year by the
manufacturer or a trained per-
son. This test covers, for exam-
ple, whether there is damage to
the filter, the vacuum cleaner is
sealed to the air and the control
equipment works properly.
9 Further information
9.1
Recycling the vacuum
cleaner
cleaner
Make the old cleaner unusable
immediately.
1. Unplug the cleaner and cut
immediately.
1. Unplug the cleaner and cut
the power cord.
Do not discard of electrical ap-
pliances with household waste.
pliances with household waste.
As specified in European Direc-
tive 2002/96/EC on old electrical
tive 2002/96/EC on old electrical
and electronic appliances, used
electrical goods must be col-
lected separately and recycled
ecologically.
Contact your local authorities or
your nearest dealer for further
information.
electrical goods must be col-
lected separately and recycled
ecologically.
Contact your local authorities or
your nearest dealer for further
information.