Oreck XL2800H2 Manual De Usuario

Descargar
Página de 8
SAVE SERVICE CALLS...CHECK THESE FIRST:
• Is the disposable filter dust bag full?
• Are pores of filter dust bag clogged with powder or fine dust?
• Is anything clogging the revolving brush, lower tube, intake
opening, fan housing or connector assembly opening?
• Is the belt in place and turning the brush?
• Are the brush ends in the proper location?
• Does the brush turn freely? Are hair, string or rug fibers wound
around the brush?
8
T
roubleshooting 
G
uide
C
LEANER
WILL NOT RUN
C
LEANER
DOES NOT PICK UP
Not plugged in
properly.
No electricity in
wall outlet.
Plug not firmly in
handle assembly.
Filter bag is full.
Nozzle or intake
pivot clogged. 
Belt is broken or
stretched.
Brush is worn.
Bag tube clogged.
Bag pores are
clogged with fine
dust.
Impeller fan is
broken.
Revolving brush is
not even at both
ends.
Be sure cleaner is
firmly plugged 
into wall outlet.
Check electrical
source–fuse or 
circuit breaker.
Plug firmly in
handle assembly.
Replace filter bag.
See “To Install
Paper Filter Dust
Bag.”
Clear obstruction.
Replace belt.
Replace brush if
bristles do not
extend beyond
base plate.
Clear obstruction.
Change bag.
Return to Service
Center for repair.
Check bearing
seal. Make sure
words “old” or
“new” match at
each end.
P
ROBLEM
P
OSSIBLE
S
OURCE
A
REAS TO
C
HECK
Whenever calling, please be sure to have your model and
serial number from data plate. 
CALL CUSTOMER SERVICE HOT LINE
US: 1-800-989-3535
CANADA: 1-888-676-7325
ALL OTHER SERVICING SHOULD BE DONE BY AN
ORECK AUTHORIZED SERVICE CENTER.
WARNING: Unplug cord from
electrical outlet before servicing.
©2002 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and
registered trademarks are owned and used under the authorization of Oreck Holdings, LLC.
75268-05 REV D
12/02 ECN# R-6815