Sennheiser EW 300 IEM G3 Manual De Usuario

Descargar
Página de 30
Specifications
26
Approved by
NT 2-3 mains unit
In compliance with
The mains unit is certified in accordance with the legal safety requirements of Europe, the United States, Canada, Russia
and Japan.
Connector assignment
Canada
Industry Canada
RSS 210,
IC: 2099A-G3SREK
limited to 806 MHz
USA
FCC-Part 74  FCC-ID: DMOG3SREK 
limited to 698 MHz
Input voltage
100 to 240 V~, 50/60 Hz
Current consumption
max. 120 mA
Output voltage
12 V 
Secondary output current
400 mA
Temperature range
−10°C to +40°C
Europe
EMC
EN 55022, EN 55024, 
EN 55014-1/-2
Safety
EN 60065
USA
  47 CFR 15 subpart B
Canada
ICES 003
Audio
Other connectors
¼” (6.3 mm) stereo jack plug, 
balanced (Audio In/Loop out)
XLR-3F connector, 
balanced (Audio In)
DC connector for 
power supply
¼” (6.3 mm) mono jack plug, 
unbalanced
¼” (6.3 mm) stereo jack plug 
for headphone output
2
1