Sears 153.321543 Manual De Usuario

Descargar
Página de 32
FIGURE 16.
5.  Remove the screws from terminal 2 of the element, and 
move the looped end of the wire aside.
FIGURE 17.
6.  The buss bar is labeled 5500 W. Place the buss bar over 
terminals 2 and 3 with the 5500 W visible. Install the extra 
screw provided into terminal 3.
FIGURE 18.
7.  The wire removed from terminal 2 has a looped end. It must 
remain looped and now be placed (as shown) on top of the 
buss bar, over the opening of terminal 2, and secured using 
the remaining screw.
FIGURE 19.
8.  Tighten terminals 2 and 3 to ensure proper electrical  
 
connection.
Failure to tighten terminal screws can cause a fire which can 
result in DEATH, SERIOUS bODILy INjURy, OR PROPERTy 
DAMAGE.
9.  Replace terminal cover on thermostat making sure that the 
locking tabs on the terminal cover are in place.
Make sure the thermostat is flush against the tank, the terminal 
cover  is  in  place,  and  the  insulation  is  replaced.  Failure  to  
do so can result in DEATH, SERIOUS bODILy INjURy, OR
PROPERTy DAMAGE.
10.  Replace the insulation cap with handle so that it completely 
covers the thermostat and element.
FIGURE 20.