B.   *Condensation may be seen on pipes in humid weather or 
pipe connections may be leaking.
C.   *The anode rod fitting may be leaking.
D.   Small amounts of water from temperature-pressure relief 
valve may be due to thermal expansion or high water 
pressure in your area.
E.   *The temperature-pressure relief valve may be leaking at 
the tank fitting.
F.   Water from a drain valve may be due to the valve being 
slightly opened.
G.   *The drain valve may be leaking at the tank fitting.
H.   Combustion products contain water vapor which can 
condense on the cooler surfaces of the tank. Droplets 
form and drip onto the burner or run on the floor. This is 
common at the time of start-up after installation and when 
incoming water is cold.
I.   Water in the water heater bottom or on the floor may be 
from condensation, loose connections, or the relief valve. 
DO NOT replace the water heater until a full inspection 
of all possible water sources is made and necessary 
corrective steps taken.
Leakage from other appliances, water lines, or ground 
seepage should also be checked.
To check where threaded portion enters tank, insert cotton 
swab between jacket opening and fitting. If cotton is wet, 
follow draining instructions in the “Draining and Flushing” 
section and then remove fitting. Put pipe dope or teflon tape 
on the threads and replace. When you are finished, follow 
the steps in “Filling the Water Heater” in the Installation 
Instructions earlier in this manual.
Teflon
®
 is a registered trademark of E.I. Du Pont De Numours and Company.
Leakage  Checkpoints                                                                                                    
                                            
FIGURE 42.
Read this manual first. Then, before checking the water heater, 
make sure the gas supply has been turned “OFF”, and never turn 
the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely filled with 
water.  To prevent damage to the tank, the tank must be filled 
with water.  Water must flow from the hot water faucet before 
turning “ON” gas to the water heater.  
A.  Water at the draft hood is water vapor which has condensed 
out of the combustion products.  This is caused by a problem 
in the vent.  Contact a qualified technician.
A
C
B
D
E
F
G
H
I
6” (152.4 mm)
MAXIMUM AIR GAP