RECOVERY CAPACITIES
MODEL
TEMPERATURE RISE - DEGREES F - GALLONS PER HOUR
NUMBER
CAPACITY
INPUT
EFFICIENCY
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
HE45-100
45
100,000
95%
288
230
192
165
144
128
115
105
96
N/A
N/A
HE45-130
45
130,000
95%
374
299
249
214
187
166
150
136
125
N/A
N/A
HE80-130
80
130,000
95%
374
299
249
214
187
166
150
136
125
N/A
N/A
HE119-130
119
130,000
95%
374
299
249
214
187
166
150
136
125
N/A
N/A
HE45-160
45
160,000
95%
461
368
307
263
230
205
184
167
154
142
132
HE80-160
80
160,000
95%
461
368
307
263
230
205
184
167
154
N/A
N/A
HE119-160
119
160,000
95%
461
368
307
263
230
205
184
167
154
N/A
N/A
HE45-199
45
199,000
95%
573
458
382
327
286
255
229
208
191
176
164
HE80-199
80
199,000
95%
575
460
384
329
288
256
230
209
192
N/A
N/A
HE119-199
119
199,000
95%
575
460
384
329
288
256
230
209
192
N/A
N/A
Recovery rating is based on a recovery efficiency obtained in an UL laboratory.
This model exceeds the minimum NAECA energy factor requirements of ASHRAE 90.1b-1992.
This model exceeds the minimum NAECA energy factor requirements of ASHRAE 90.1b-1992.
Commercial water heaters
from Rheem-Ruud
MAXIMUM DELIVERY
(in gallons) (Includes useable storage and recovery for indicated times)
MODEL
TEMP.
5
10
15
20
30
45
1
2
3
MIN. TO RECOVER
NUMBER
CAPACITY
INPUT
EFFICIENCY
RISE
MIN.
MIN.
MIN.
MIN.
MIN.
MIN.
HR.
HR.
HR.
CONTENTS
HE45-100
45
100,000
95%
100°
41
51
60
70
89
118
147
262
377
23
HE45-130
45
130,000
95%
100°
44
56
69
81
106
144
181
331
481
18
HE80-130
80
130,000
95%
100°
68
81
93
106
131
168
206
355
505
32
HE119-130
119
130,000
95%
100°
96
109
121
134
159
196
234
383
533
48
HE45-160
45
160,000
95%
100°
47
62
78
93
124
170
216
400
584
15
HE80-160
80
160,000
95%
100°
71
87
102
117
148
194
240
424
609
26
HE119-160
119
160,000
95%
100°
99
115
130
145
176
222
268
452
637
39
HE45-199
45
199,000
95%
100°
51
70
89
108
146
203
261
490
719
12
HE80-199
80
199,000
95%
100°
75
94
114
133
171
229
286
516
747
21
HE119-199
119
199,000
95%
100°
103
122
141
161
199
257
314
544
774
31
DIMENSIONAL INFORMATION
(All dimensions shown in inches)
MODEL
APPROX. SHIPPING
NUMBER
HEIGHT
WIDTH
DEPTH
VENT
WEIGHT (LBS.)
HE45-100
42
23-1/2
32
2
†
175
HE45-130
42
23-1/2
32
2
†
175
HE45-160
42
23-1/2
32
3
175
HE45-199
42
23-1/2
32
3
175
HE80-130
72
23-1/2
32
2
†
235
HE80-160
72
23-1/2
32
3
235
HE80-199
72
23-1/2
32
3
235
HE119-130
73
27
36
2
†
405
HE119-160
73
27
36
3
405
HE119-199
73
27
36
3
405
†
Models with inputs of 100,000 kBtu and 130,000 kBtu are certified to vent with 2” Schedule 40 PVC,
CPVC or ABS pipe.
CPVC or ABS pipe.
CLEARANCES TO COMBUSTIBLES
MODEL
REAR /
NUMBER
SIDES
FRONT*
TOP
HE45-100
0
0
0
HE45-130
0
0
0
HE45-160
0
0
0
HE45-199
0
0
0
HE80-130
0
0
0
HE80-160
0
0
0
HE80-199
0
0
0
HE119-130
0
0
0
HE119-160
0
0
0
HE119-199
0
0
0
* 24" service clearance recommended