Grindmaster 850 Manual De Usuario

Descargar
Página de 16
American Metal Ware Hot Water Boiler
Page 8
A)
B)
C)
Overfilling of water tank when power is of
f.
Overfilling of water tank only when power to unit is on.
Auto refill fails to fill water t
ank.
PROBLEM
IV)  
T
rouble Shooting 
Auto Refill, Low W
ater Cutof
f, and Dual
Level Control System
POSSIBLE CAUSE
SER
VICE CHECK
REMEDY
1)
2)
1)
2)
3)
4)
1)
2)
Fill solenoid valve leaking due to dirt or scale holding valve open, or worn plunger seat.
Fill solenoid valve inst
alled backwards.
High electrode coated with scale, or faulty
.
Missing or faulty  common connection for electrode circuit (“C”  terminal to met
al 
enclosure).
Fill valve connected to “HEA
T”
terminal.
Dual Level printed circuit board faulty
.
No power at equipment.
No water at equipment.
V
isual.  W
ater entering
tank continuously
, and
usually slowly
.
V
isual.
Jumper from “HI”
terminal
to met
al enclosure stop
s
fill.
Jumper “C” terminal (next to XL) to met
al 
enclosure stop
s fill.
V
isual.
Jumper from “HI”
to “C”
does not stop fill.
Nothing operates on machine.
“Crack” fitting at  water inlet for pressure check.
Disassemble and clean out.  May require new plunger assembly
.  Caution
is advised to avoid damage to valve. See valve instruction sheet.
On valves without integral strainer:
Inst
all so that port marked “IN” is
connected to out
side fresh water
supply
.
On valves with integral strainer:
Inst
all so that arrow point
s in
direction of t
ank, away from fresh
water supply
.
Remove electrode assembly
.  Clean both
electrodes.  If still no remedy and connections are good, replace assembly
.
Make good secure connection.  May  require cleaning or replacement.
Connect “BLACK”
wire lead to “FILL”
terminal.
Replace Dual Level Control.
Make sure main switch(es), fuse(s), circuit breaker(s) provide power to unit, that machine’
s circuit
breaker is OK
and power switch, if
provided, is on.
Make sure all water supply line valves are open.