T8611G CHRONOTHERM
®
 IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
11
69-1406—1
System on indicator 
(flame=heat, 
snowflake=cool) is 
displayed, but no 
warm or cool air is 
coming from the 
registers.
Heating or cooling equipment is 
not operating.
Verify operation of heating or cooling equipment in self-test.
Outdoor tempera-
ture not displayed
a
Option not activated.
Enter Installer Setup number 24 and set to 1. Thermostat must 
have OT terminals and a C7089B1000 installed.
Outdoor 
temperature 
display is incorrect
a
Outdoor sensor is connected 
incorrectly.
Refer to C7089B1000 Installation Instructions and check wiring 
between the thermostat and sensor.
Wrong sensor.
Replace sensor with C7089B1000 Sensor.
a
Select models.
Table 6. Troubleshooting Guide. (Continued)
Symptom
Possible Cause
Action