Performance Data 
16
3A0427B
Performance Data
Use the following charts to choose the best ratio for your 
application, depending on the desired fluid pressure 
range and pressure losses due to flow rate, fluid viscos-
ity, and fluid line size.
The ratio determines the fluid pressure to air pressure 
response curve:
A higher ratio (1:3) will have a flatter response curve 
and will not react as strongly to changes in the air 
pilot signal. 
A lower ratio (1:1) will have a steeper response 
curve but will cover a wider range of fluid pressure. 
0
20
40
60
80
100
(0.7, 7.0)
(0.56, 5.6)
(0.49, 4.9)
(0.42, 4.2)
(0.35, 3.5)
(0.28, 2.8)
(0.21, 2.1)
(0.14, 1.4)
(0.07, 0.7)
10
20
30
40
50
60
80
90
70
(0.63, 6.3)
0
(0.56, 5.6)
(0.42, 4.2)
(0.28, 2.8)
(0.14, 1.4)
Pilot Air Pressure
R
e
gulate
d
 Fluid 
Outle
t Pres
sure
psi
(MPa, bar)
psi
(MPa, bar)
1:1 Ratio, 
High Port
1:2 Ratio
1:3 Ratio
1:1 Ratio, 
Low Port