White Rodgers 37-5086A Manual De Usuario

Descargar
Página de 8
6
Figure 13. Back of thermostat
Option switches
3-pin connector
6-pin connector
Batteries
W14
W22
(Group A)
(Group B)
ATTACH THERMOSTAT TO SUBBASE
IT IS RECOMMENDED THAT YOU SET OPTION
SWITCHES TO DESIRED POSITION BEFORE ATTACH-
ING ON SUBBASE 
(see OPERATION). IT IS ALSO
RECOMMENDED THAT YOU PROGRAM THE
THERMOSTAT WITH BATTERIES INSTALLED BE-
FORE ATTACHING ON SUBBASE 
(see OPERATION
GUIDE
 for programming instructions).
USE 
SYSTEM
SWITCH
 TO TURN THERMOSTAT OFF BE-
FORE ATTACHING THERMOSTAT TO WALL.
FAILURE TO TURN THERMOSTAT OFF BEFORE
ATTACHING TO WALL MAY CAUSE EQUIPMENT
DAMAGE DUE TO RAPID COMPRESSOR CY-
CLING.
To attach thermostat to subbase, line up the plastic snap
guides at the bottom of the thermostat and the three
connector pins on the thermostat with the connectors
near the bottom left section of the subbase (when viewed
from the front). Gently pivot the thermostat up until the six
pin connectors and the plastic snaps lock into place (see
fig. 12). Be gentle when attaching thermostat. If the
thermostat does not seem to be attaching to the subbase
easily, make sure that the connector pins and plastic
snaps are properly aligned, and that excess wire is
pushed into the wall. Damage to the thermostat may
occur if force is used.
CAUTION
!
OPERATION
SYSTEM CONFIGURATION
A. SET GROUP A OPTION SWITCHES
 DO NOT REMOVE THE “AA” BATTERIES WHEN
CHANGING GROUP A OPTION SWITCHES. Any
time Group B option switches are changed, the bat-
teries must be removed for a minimum of two minutes.
1.
Total Keypad Activity
2.
Total Keypad Lockout — All thermostat buttons are
disabled.
3.
Limited Temperature Range — Temperature may
be raised or lowered within programmed temperature
limits (temperature adjustment cannot exceed the
lowest cooling or highest heating program tempera-
tures).
When thermostat is in Limited Temperature Range
only the following buttons are disabled:
ADV
PRGM
HOLD
TEMP
SET
DAY
NOTE
ON
1
2
Switch #1 OFF
Switch #2 OFF
ON
1
2
Switch #1 ON
Switch #2 OFF
ON
1
2
Switch #1 OFF
Switch #2 ON
B. SET GROUP B OPTION SWITCHES
ANY TIME GROUP B OPTION SWITCHES ARE
CHANGED, THE “AA” BATTERIES MUST BE REMOVED
FOR A MINIMUM OF 2 MINUTES. DO NOT REMOVE
THE BATTERIES WHEN CHANGING GROUP A OP-
TION SWITCHES.
1.
Automatic Changeover (Heating/Cooling Systems
Only)
 — enables thermostat to automatically switch
between heating and cooling programs to maintain
desired room temperature.
ENGAGE TWO LOWER GUIDES;
PIVOT UP
Figure 12. Attaching thermostat to subbase
NOTE
ON
1
2
3
Switch #1 ON
Switch #2 OFF
Switch #3 (see step B5)