°F
Set Temperature
Main Controller
 
239-44509-00
 
In Use
Priority
endless hot water system
CAUTION: Hotter water increases the risk
of scald injury. Before changing temperature
setting, see instruction manual.
 
Main or Optional Remote Control for Residential Models (Fig. 6) 
 
Temperature Control(s) Installation: 
 
1.  Determine how many controls will be installed and suitable location(s) for each.  The controls may 
be wired in series or parallel depending on the distance from the water heater to the controls. 
 
2.  Mark the holes on the wall using the control mounting plate and drill two mounting holes using a 
3/32” (2.4 mm) drill bit and a clearance hole for the cable using a ¼” (6.4 mm) drill bit. 
 
3.  Run the cable from the control to the water heater or another control, which ever is closer or more 
convenient. 
 
4.  Remove the face plate from the remote control by inserting a screwdriver in the slot and twisting 
open. 
 
5.  Connect the cable to the terminal screws of the remote control. 
 
6.  Mount the control to the wall using the holes drilled and with the screws supplied.  Note:  Plastic 
wall anchors may be required if the control is not located over a stud when mounting on 
wallboard. 
 
Note:  If the cable cannot be run inside the wall cavity, then the plastic knockout should be removed from 
the top or bottom of the control to allow flush mounting with the wall. 
 
7.  Disconnect the power from the water heater and remove the front cover. 
 
8.  Remove the plastic cover from the PCB and electrical connections. 
 
25