APPROXIMATE 
TIME/TEMPERATURE 
RELATIONSHIPS IN SCALDS 
120°F (49
°C)  More than 5 minutes
125°F (52
°C)  1½ to 2 minutes 
130°F (54
°C)  About 30 seconds 
135°F (57
°C)  About 10 seconds 
140°F (60
°C)  Less than 5 seconds
145°F (63
°C)  Less than 3 seconds
About 1½ seconds 
150°F (66
°C) 
About 1 second 
155°F (68
°C) 
 
FIRST AID FOR SCALDS 
 
1.  Remove all wet clothing quickly.  Wet clothing retains the heat. 
2.  Apply cold water to burned area for 30 minutes to reduce the heat in the skin and prevent deeper 
burning.  Never use butter, oils, or ointment to cover the burn.  They may retain the heat. 
3.  Use a blanket to keep the scalded person warm. 
4.  Seek medical advice. 
 
ERROR MESSAGES ON REMOTE TEMPERATURE CONTROL DISPLAY 
 
The Bradford White EVERHOT
® tankless water heaters have the ability to monitor and display any 
operating faults on the remote temperature control display.  The error messages will display on the 
monitor and will assist in servicing the water heater.  The following is a listing of the error codes that may 
flash on the remote monitor in case of a malfunction with the water heater.  Please quote the code 
displayed when calling for service. 
 
Code 
Displayed 
Fault Remedy 
10 
Air supply or exhaust blockage 
Check for a restriction in the exhaust vent.   
11 
No Ignition 
Check to make sure the gas supply is on to the 
water heater. 
12 
Flame Failure, grounding failure 
Make sure gas is turned on at the water heater; 
check for obstructions in exhaust vent. 
14 
Thermal Fuse 
Heat exchanger overheated 
16 Over 
Temperature 
Warning Excessive temperatures, wrong dip switch 
setting, incorrect manifold pressure or gas type. 
32 
Outlet water temperature faulty 
Outlet sensor or wiring may be defective 
33 
Heat exchanger outlet water temperature 
faulty 
H.E. outlet sensor or wiring may be defective. 
34 
Combustion air sensor faulty 
Thermistor or wiring faulty 
52 
Modulating Solenoid Valve signal 
abnormal 
Check gas control and wiring 
61 
Combustion Fan Failure 
Combustion fan or wiring faulty 
71 
Solenoid Valve Driving Circuit Faulty 
Check all gas solenoids and wiring 
72 
Flame Sensing Device Faulty 
Lack of flame sense – check flame rod and 
wiring connections. 
LC 
Scale build-up in Heat Exchanger 
Build up of lime scale in heat exchanger – 
needs to be flushed. 
(00) 
(When checking maintenance code 
history, “00” is substituted for “LC”). 
 
If any of the above error codes are seen flashing on the remote display, call for service
 
 
WARNING
 
 
Failure to remedy faults may result in severe burns, scalds, and/or death. 
 
34