Bradford-White Corp SDW2TW50T Manual De Usuario

Descargar
Página de 16
5
This section is intended to provide a better understanding of the solar thermal design
application and how it varies from the base model listed on page 3. 
Solar Thermistor Wiring 
The solar with gas backup water heater comes provided with two sets of twisted 
thermistor wiring.  They are color coded for ease of use.
The solar with gas backup models come with an internal double-wall heat exchanger.
Brown thermistor wiring is provided under an access panel between the solar heat 
exchanger connections.  A thermistor 
(not included) wired to this pair can be
connected to the solar control to determine the temperature differential between the 
tank and the solar collector.  The control can then activate a circulator to heat the tank. 
To assist in connecting the thermistor, the end has a supplied wire nut.  A bracket and 
plate is supplied to mechanically press the thermistor against the tank wall. 
A twisted orange wire set is provided under the upper access panel.  Some solar 
controllers have locations for a second tank temperature input.  This is not used for 
controlling the solar thermal system, but helps the end user understand what an 
anticipated delivered temperature may be. 
EcoStor2™ Solar  
Thermistor Wiring 
Brown and Orange twisted 
thermistor wires 
Upper Access Location 
(Orange Twisted Pair) 
Lower Access Location 
(Brown Twisted Pair) 
5