SECTION VI:  ELECTRICAL CONNECTIONS 
 
 
WARNING
 
Turn off or disconnect the electrical power supply to the water heater before servicing.  Label all 
wires prior to disconnection when servicing controls.  Wiring errors can cause improper and 
dangerous operation.  Verify proper operation after servicing. 
 
All electrical wiring must be installed and grounded in accordance with local codes, or in the 
absence of local codes, the National Electrical Code, ANSI/NFPA 70 and/or CSA C22.2 Electrical 
Code. 
 
The water heater must be wired to a 120 VAC, 60 Hz, 15A power supply.  The water heater should be 
connected to a GFI outlet and wired on a separate circuit and breaker.  A strain relief will be required for 
the line cord.  Do not plug the line cord into a receptacle that can have the power supply interrupted by a 
switch that is used to control lights or another appliance. 
 
If wiring in conduit is required, install an electrical conduit connector.  A disconnect switch should be 
provided near the water heater for servicing.  Connect the wires exactly as shown in the wiring diagram of 
this manual and on the inside cover panel.  The black wire is the hot leg; the white wire is neutral.  A 
green screw is provided in the junction box for the green wire ground connection. 
 
 
CAUTION
 
Do not energize the electric circuit before the water heater tank is filled with water.