Bradford-White Corp U2TW50T*FRN Manual De Usuario

Descargar
Página de 52
 Page 32 
Blower Temperature Switch Testing (cont’d)
Switch Setting
Opens on rise @ approximately 165
o
F
Auto resets on fall @ approximately 160
o
F
Cool switch to
below 160
o
F
Reconnect wire leads and ob-
serve heater operation. Do 
exhaust gas temperatures 
rise to or above 170
o
F with 
vent connected? 
Replace switch 
(see page 33). 
Disconnect wire leads to 
switch. Using multi-meter set 
to the ohms setting. Is there 
continuity between the switch 
terminals? 
Do switch 
contacts
open?
Exhaust
temperature 
is too hot.  
Do switch con-
tacts open? 
Replace switch 
(see page 33). 
Switch OK 
Common causes for high 
exhaust temperature
1.  Vent length is below mini-
mum allowable 
2.  Vent diameter not to speci-
fication 
3. Restricted dilution air inlet
4.  Missing or deteriorated flue 
baffle
5.  Gas pressure is out of
specification
N
N
N
N
Y
Y
Y
Y
Blower Temperature Switch Testing 
32