Burner Cleaning Procedure (cont’d) 
Step 12. 
Reassemble the burner assembly and reinstall into the water heater. 
Restore gas supply and check for gas leaks. 
Step 13. 
To resume operation, follow the instructions located on the water heater 
lighting instruction label.  Or, use the lighting instructions located in the water heater 
installation and operating manual.
Pilot Inspection, Testing and Replacement 
Step 1. 
Move the gas control power switch to the “OFF” 
position
Step 2.  
Unplug the water heater from the wall outlet. 
Step 3. 
Turn off the gas supply to the water heater. 
Step 4. 
Remove the outer door. 
Step 5. 
Remove the (4) 1/4” hex drive screws holding the 
right side inner door in place. 
Step 6.
Disconnect the pilot tube 
using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas 
control.
Pilot Maintenance 
Gas control power 
switch 
Outer door 
(4) 1/4” hex drive 
screws
Right side 
inner door 
Pilot and main 
feedlines 
Damper (water 
heater) power cord 
17