Bradford-White Corp UTW465S60FR*N Manual De Usuario

Descargar
Página de 52
 Page 33 
Blower Temperature Switch Replacement 
Step 1. 
Move the gas control power switch to the 
  “OFF” 
position. 
Step 2. 
Remove the three screws (Phillips screw 
driver) from the control access cover on  the blower as-
sembly and remove cover. 
Step 3. 
Locate blower temperature switch.  
Step 4. 
Disconnect red and yellow wire leads from 
the switch.
Step 5. 
With an appropriate tool such as side cut-
ters, snip the retaining lug from the 
blower housing to allow removal of 
temperature switch. 
Step 6. 
Remove switch from blower housing. 
Step 7. 
Install new switch. Be sure switch is prop-
erly seated in mounting area. 
Step 8. 
Reconnect red and yellow wires to new switch. Wires are inter-
changeable with either terminal. 
Step 9. 
Position the gas control power switch to the “ON” position and
verify proper heater operation.
Step 10. 
Replace control access cover from step 2. 
WARNING
115 volt potential exposure. Use caution making voltage checks to avoid 
personal injury.
Gas control power 
switch 
Control access 
cover
Blower temperature 
switch location
Snip retaining lug from 
blower housing 
Blower Temperature Switch Replacement 
33