Gas Control & Thermal Well Removal From Water Heater (cont’d)
Step 
4. 
Disconnect the pilot tube 
using a 7/16” wrench and the main burner 
feedline with a 3/4” wrench from the gas 
control.
Step 5. 
Disconnect the wire harnesses and spark igniter/
flame sense wire from the gas control.
Step 6. 
Remove the gas control & thermal well by rotating 
the flats of the Thermal Well counter clockwise using a 1-5/16” 
wrench.
Gas Control Removal From Thermal Well 
Following the steps below allows for the removal of the gas control from the thermal 
well without removing the thermal well from the tank. 
Step 1. 
Move the gas control power switch to the “OFF” 
position.
Step 2. 
Unplug the water heater from the wall outlet. 
Gas Control Removal 
Pilot and main 
feedlines 
Spark igniter/flame 
sensor wire 
Gas control
Flats of thermal
well
Gas control power 
switch 
TTW (water heater) 
power cord 
37