Bradford-White Corp U1TW50S*FRN Manual De Usuario

Descargar
Página de 52
 Page 25 
Pilot Inspection, Testing and Replacement (cont’d)
Step 15. 
Inspect the pilot tubing and pilot orifice for blockages: 
a) Remove ferrule nut from the bottom of 
the pilot assembly using a 7/16" wrench. 
b) Remove the pilot tube and pilot orifice. 
c) Inspect the pilot tubing and pilot orifice 
for blockages.  Clean or replace, as neces-
sary.
Step 16.  Reassemble the pilot assembly and install it on the main 
burner.  Reinstall the burner assembly into the combustion chamber. Re-
store the gas supply and check for gas leaks. 
Step 17. 
To resume operation, follow the instructions located on the wa-
ter heater lighting instruction label.  Or, use the lighting instructions located 
in the water heater installation and operating manual.  
Pressure Switch Testing
Step 1. 
Move the gas control power switch to the “OFF” position. 
Step 2. 
Remove the three screws (Phillips screw driver) from the con-
trol access cover on  the blower assembly and remove 
cover (see photo 1). 
Step 3. 
Carefully remove pres-
sure switch from blower housing (see photo 2).
Pressure Switch Testing 
Gas control power 
switch 
WARNING
115 volt potential exposure. Use caution making voltage checks to avoid 
personal injury.
1
2
Pressure Switch 
25