Troubleshooting continued-
 
 
LED Status
Control Status
Probable Cause
Six  f lashes,  t w o 
f lashes, three 
second pause 
(Sof t   Lockout )
Relay not  w orking properly 
during burner operat ion, 
syst em aut o reset s aft er 
(5) minut es
Fault y relay
Six  f lashes,  t hree 
f lashes, three 
second pause 
(Sof t  Lockout )
Pilot  f lame ext inguished, 
syst em aut o reset s aft er 
(5) minut es
1. Unst able pilot
2. Pilot  t ube block or restrict ed
3. Oxidat ion build-up on pilot  elect rode
4. Wire damage to pilot  assembly or bad 
connect ion at  gas valve
5. Insuf f icient   combust ion  air
Six f lashes, f our 
f lashes, three 
second pause
Undesired f alse pilot  f lame 
sensed, syst em auto 
resets
Pilot  valve st uck in open posit ion
Seven f lashes, 
three second 
pause
Flammable vapor sensor or 
reset t able  t hermal  sw it ch 
f ault   det ect ed,  see 
w arning label
1. Flammable vapor present
2. Flammable vapor sensor exposed t o 
excessive moist ure
3. Flammable vapor sensor exposed t o 
ext reme ambient  t emperat ure
4. Reset t able  t hermal  sw it ch  open
Eight  f lashes, one 
flash, t hree 
second pause
Flammable vapor sensor 
out  of  specif icat ion, 
possible short
1. Flammable vapor sensor out  of  
specif icat ion
2. Possible short  in f lammable vapor sensor 
or reset t able  t hermal  sw itch  w iring
Eight  f lashes, 
t hree  f lashes, 
three second 
pause
Thermal w ell sensor 
damaged or unplugged or 
gas valve electronics fault  
det ected
1. Damage t o t hermal w ell w ires
2. Thermal w ell sensor resist ance out  of 
range
3. Replace t hermal w ell
4. Verif y cont rol is not  w et  or physically 
damaged
5. Reset   cont rol  on/of f   sw it ch
6. Replace elect ronic module if  8-3 error 
persist s
Eight  f lashes, f our 
f lashes, three 
second pause
Gas  valve  f ault   det ect ed
1. Verif y cont rol is not  w et  or physically 
damaged
2. Reset   cont rol  on/of f   sw it ch
3. Replace gas cont rol if  8-4 error persist s
 
 
Fault Probable 
Cause 
Resettable Thermal Switch Tripped (Open) 
1.  Insufficient combustion air 
2.  Flammable vapors present