screws.  Verify that both the left and right side inner doors are properly positioned and 
sealed against the combustion chamber. 
Step 8.  
Re-install the outer door. 
Step 9. 
To resume operation, follow the instructions located on the water heater 
lighting instruction label.  Or, use the lighting instructions located in the water heater 
installation and operating manual.
ScreenLok
®
 Flame Arrestor Cleaning Procedure 
Step 1. 
Move the gas control power switch to the “OFF” position and unplug the 
water heater from the wall outlet. 
Step 2. 
Remove the outer door. 
Step 3. 
Remove the right side inner door per the Inner Door Removal Procedure 
on page 32. 
Step 4. 
Disconnect the pilot tube using a 7/16” wrench and the main burner 
feedline with a 3/4” wrench from the gas control. 
Step 5. 
Disconnect the spark igniter/flame sensor wire from gas control. 
Step 6. 
Remove the burner assembly from the combustion chamber. 
Step 7. 
Clean the ScreenLok
®
 flame arrestor using a stiff brush, compressed air, 
and/or a shop vacuum to remove any scale or other debris accumulation.  Using a soft 
brush, clear jacket openings from any dirt, dust, restrictions, or other obstructions. 
Step 8. 
Remove any debris from the burner assembly following the Burner 
Cleaning Procedure on page 15. 
Step 9. 
Re-install the burner assembly. 
Step 10. 
Reconnect the main and pilot tubing and spark igniter wire to the gas 
control.
Step 11. 
Re-install the inner door per the Inner Door Installation with Gasket Pro-
cedure on page 34. 
Step 12. 
To resume operation, follow the instructions located on the water heater 
lighting instruction label.  Or, use the lighting instructions located in the water heater 
installation and operating manual.
Arrestor Cleaning 
49