1 23
BW C
4
VA
1
SERIES
USAGE
FUEL
ALTITUDE
LOCATION
REVISION
HEAT
EXCHANGER
FIRING
MODE
OPTIONS
CODE
PUMP
OPTIONS
B (std.)
P
C=On-Off (std.)
K=Two-Stage
L (std.)
N (std.)
S
SIZE
VN
P
A
C=Convertible
0
0
0
2
3
4
0
0
0
0
0
0
Copper-Brute II (200-400)
Water Heater Specifications
(1-3) Model Series Designation
B W C = Copper Brute II
(4) Usage
V = Volume Water
(5-8) Size
0 2 0 0 = 199,900 BTU/Hr. input
0 3 0 0 = 299,900 BTU/Hr. input
0 4 0 0 = 399,900 BTU/Hr. input
(9) Fuel
N = Natural Gas
P = Propane
(10) Altitude
A = 1-10,000 feet
(11) Location
C= Convertible
(12) Firing Mode
C = On-Off (standard on all models)
K = Two-stage (optional on all models)
(13) Revision
1 = First Revision of Design
(14) Heat Exchanger
B = Glass-lined cast iron headers / copper / bronze trim
P = Glass-lined cast iron headers / cu-nickel / bronze trim
(15) Option Code
L = Low Temp. Control
(16) Pump Options
N = Pump mounted water heater, normal water pump
S = Pump mounted water heater, soft water pump
Model Character Designation
Gas
2
Water
2
Shipping
Model
Input
1
Output
1
90°F
50°C
100°F
56°C
140°F
78°C
Conn.
Conn.
Weight
Numbers
BTU/Hr.
BTU/Hr.
GPH
LPH
GPH
LPH
GPH
LPH
inches
inches
(lbs.)
(kg)
BWCV0200
199,900
169,900
227
858
204
771
146
552
3
4
1
1
2
290
132
BWCV0300
299,900
254,900
340
1285
306
1157
219
828
3
4
1
1
2
320
145
BWCV0400
399,900
339,900
453
1712
408
1542
291
1100
3
4
1
1
2
350
159
Copper-Brute II Models
1. Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.
2. Dimensions are nominal.
Note: GPH = gallons per hour, LPH = liters per hour.
WATER TEMPERATURE RISE IN DEGREES
Note: GPM= gallons per minute, LPM=liters per minute
Water Flow Data
Model
Flow
Flow
Flow
Flow
Flow
Flow
Numbers
GPM
LPM
GPM
LPM
GPM
LPM
BWCV0200
45
170
35
133
23
87
BWCV0300
45
170
35
133
23
87
BWCV0400
45
170
35
133
23
87
HARD WATER
NORMAL WATER
SOFT WATER
Model Numbers
Firing Stage
BWCV0200
On/Off*
BWCV0300
On/Off*
BWCV0400
On/Off*
Firing Rates
* Two-stage available as an
option.