ACCESSING SERVICE MODE ON THE WATER HEATER DISPLAY (FOR SERVICE PERSONNEL ONLY) 
 
The display has a “service mode” for changing the maximum setpoint and accessing information in aiding servicing of the 
water heater.  This procedure is for service and installation personnel only.  To enter the Service Mode, follow the steps 
illustrated below: 
 
Step 1:  Press “Select” and “Temperature Up” buttons together and hold for 3 seconds until “Max Setpoint” is shown in the 
display.  
 
Step 2: Pressing “Select” button will change display to next mode. 
 
SELECT
SET
Status
°F
idle
Operational
Water
Temp
SELECT
SET
Status
idle
Operational
"Max Setpoint"
Next  to Temperature
Setpoint  value.
Max
Setpoint
The following procedure is for service and installation personnel only.  Resetting lockout conditions without 
correcting the malfunction can result in a hazardous condition.
 
WARNING
30 Seconds after the last button press, the display will automatically return to the “User Mode”.  Simultaneously 
pressing the “Select” and “Temperature Up” buttons will switch the display immediately to the “User Mode”.
 
NOTICE