Complaint
Cause
remedy
user
Qualified serViCe agenCy
*Water not hot enough
Thermostat set too low.
Set thermostat dial to a higher 
temperature
Upper and/or lower temperature 
probe out of calibration.
Call qualified service agency
Check continuity and resistance (Ohms) 
of upper and lower temperature probes. 
replace probes if out of specification.
*Insufficient hot water
*See WATer TeMPerATUre 
COnTrOl WArnInG (on page 
12).
Thermostat set too low.
Set thermostat dial to a higher 
temperature
Upper and/or lower temperature 
probe out of calibration.
Call qualified service agency
Check continuity and resistance (Ohms) 
of upper and lower temperature probes. 
replace probes if out of specification.
Main manual gas shutoff valve 
partially closed.
Open main manual gas shutoff 
valve to fullest extent.
Heater too small for demand.
Space usage to give heater time 
to restore water temperature.
Heater recovery is slower.
Call qualified service agency
Check gas input. If incorrect, check 
for inlet air blockage and/or flue gas 
exhaust blockage.
Water temperature too hot.
Thermostat set too high.
Set thermostat to a lower setting.
rumbling.
Sediment accumulation on 
bottom of tank.
Drain a quantity of water through 
drain valve. If rumbling persists, 
call a qualified service agency.
Delime heater.
Ticking or metallic sounds.
expansion and contraction - 
normal.
Pounding or water hammer.
Air chambers in piping have 
become waterlogged. Thermal 
expansion tank damaged, 
improperly charged, or 
improperly sized.
Drain piping system and refill. 
Heater must be off while this 
is being done. Check thermal 
expansion tank charge pressure 
when the water system pressure 
is zero.
Follow the manufacturer's instructions 
for proper charging of the thermal 
expansion tank.
Water leaks.
Drain valve not closed tightly.
If drain valve cannot be closed 
tightly, replace.
If leakage source cannot be 
corrected or identified, call 
qualified service agency.
Shut off gas supply to heater 
and close cold water inlet valve 
to heater.
repair or in case of suspected tank 
leakage, be certain to confirm before 
replacing heater.
Gas odors.
Possible gas leaks.
Shut off gas supply to heater 
and call gas company at once
trouBleshooting