Emerson 1F83-0471 Hoja De Especificaciones
WR-7255-2
St. Louis, Missouri Markham, Ontario
314-553-3600
905-201-4701
www.white-rodgers.com
The Emerson logo is a trademark and
a service mark of Emerson Electric Co.
a service mark of Emerson Electric Co.
2/2
2/2
2/2
2/2
2/2
3/2
3/2
2/2
3/2
2/2
Single
Stage
Multi-
Stage
Stage
Heat
Pump
Stages
Heat/Cool
by System
Program
Options
Model
Number
Programs
Model
Selectable Performance Features
Comfort and Convenience Features
Applications
Power Source
1/1
1/1
1/1
1/1
1/1
5+2,5+1+1,Ø
1F85CA-0471
B,H
Comfort Alert
3 Wire Zone
✓ ✓
Energy Star
✓
Audible
Feedback
Millivolt
✓
Programmable
Fan
Energy Mgt.
Recovery
✓
Dual Fuel
Option
Temperature
Limits
✓
Auto
Changeover
✓
Gas/Oil/
Electric
✓
Indoor
Remote
Sensor
▼
Cool
Savings™
✓
Lighted
Display***
✓
Daylight
Savings
Adjustment
✓
Ignition
Module Reset
✓
Permanent
Memory
✓
Outdoor
Remote
Sensor
▼
5+2,5+1+1,Ø
1F85-0471
B,H
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
5+2,5+1+1,Ø
1F85-0422
B,H
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Ø
1F83-0471
B,H
✓ ✓ ✓
✓
✓
✓
✓
✓
✓
✓
Ø
1F83-0422
B,H
✓ ✓ ✓
✓
✓
✓
✓
✓
✓
✓
B =Battery, H =Hardwired, PA =Power Stealing Assist *** Optional Continuous Display Light w/Hardwire Connection
▼ Only One (1) Remote Sensor May Be Used – Either Indoor or Outdoor; or Logic Program and Indoor Remote Sensor
Dimensions
5.1"W x 3 .9"H x 1.2"D
Electrical Specifications
Rating
0 to 30 VAC, 50/60 Hz or DC
0 to 30 VAC, 50/60 Hz or DC
0.05 to 1.5 Amps (load per terminal)
2.5 Amps maximum load
(all terminals combined)
(all terminals combined)
Standard Systems
Gas, oil, electric
Gas, oil, electric
Single Stage/Heat Pump/Multi-Stage
Millivolt Systems
2 or 3 wire hydronic zone valve
Thermal Specifications
Setpoint Temperature Range:
45° to 90° F (7° to 32° C)
45° to 90° F (7° to 32° C)
80 Series Blue Rated
Differential:
0.4
° to 1.7° F
with adjustable anticipation
Operating Ambient Temperature:
32° to 105° F (0° to 40° C)
32° to 105° F (0° to 40° C)
Operating Humidity Range:
90% non-condensing maximum
90% non-condensing maximum
Shipping Temperature Range:
-4° to 150° F (-20° to 65° C)
-4° to 150° F (-20° to 65° C)
Accessories
Wall Plate F61-2634 (6.5"W x 5"H)
for 80 Series Blue
(Included with 1F85-0471, 1F85CA-0471,
1F85-0422, 1F83-0471, 1F83-0422)
for 80 Series Blue
(Included with 1F85-0471, 1F85CA-0471,
1F85-0422, 1F83-0471, 1F83-0422)
Thermostat Guard F29-0231
(For additional guard options refer to White-Rodgers
catalog at www.white-rodgers.com)
catalog at www.white-rodgers.com)
For Additional Information
Visit www.white-rodgers.com
Exclusive 4" Blue Features
Large, 4-square-inch Blue display
with easy-to-see characters
with easy-to-see characters
Active protection for systems with
ComfortAlert CA2 module compressor
diagnostics (1F85CA-0471)
ComfortAlert CA2 module compressor
diagnostics (1F85CA-0471)
Quick one-button programming
(See Automatic Schedule section in
installation instructions)
(See Automatic Schedule section in
installation instructions)
Configures as manual heat/cool,
auto changeover, heat only
or cool only
auto changeover, heat only
or cool only
Exclusive Cool Savings
™
feature
saves energy during peak A/C
demand periods
demand periods
Hydronic 2 or 3 wire zone valve
applications
applications
Exclusive battery power monitor
5-year warranty
Programming
Choice of 5/1/1 day programmable,
5/2 day or non-programmable
5/2 day or non-programmable
(1F85-0471, 1F85CA-0471, 1F85-0422)
4 time and 4 temperature settings
per program (heat & cool)
per program (heat & cool)
Energy savings up to 33%
Patented pre-programmed
software simplifies time and
temperature programming
software simplifies time and
temperature programming
Display
Large LCD with improved
contrast for easier reading
contrast for easier reading
Lighted display for easier
low-light viewing
low-light viewing
Comfort & Convenience
Optional minimum and maximum
temperature configurable
temperature configurable
Permanent program retention
during power loss
during power loss
Indefinite setpoint Hold
Air filter change indicator
(optional)
(optional)
Simple “set-up” menu to
activate optional features
activate optional features
Temporary temperature
override two-hour minimum
or until next program period
override two-hour minimum
or until next program period
(1F85-0471, 1F85CA-0471, 1F85-0422)
Soft-touch keypad
Display temperature
recalibration (+/- 4°)
recalibration (+/- 4°)
Performance
Dual-Powered…choice of
battery-powered or hardwired,
for all applications
battery-powered or hardwired,
for all applications
Selectable Energy
Management Recovery
Management Recovery
(1F85-0471, 1F85CA-0471, 1F85-0422)
Meets ENERGY STAR
®
specifications
(1F85-0471, 1F85CA-0471, 1F85-0422)
Meets California Building Code,
Title 24
Title 24
(1F85-0471, 1F85CA-0471,
1F85-0422)
Fast (FA) or slow (SL) heating
cycle anticipation
cycle anticipation
Easy-to-wire terminal block
Compressor lockout protection
Millivolt compatible
Electric heat option
BLUE
™
Universal Thermostats
Terminal Designations
RC
RH
W/E
G
Y
W2
Y2
O/B
6
L
C
1F83-0471/1F83-0422
Non-Programmable
1F85-0471/1F85CA-0471/1F85-0422
5/1/1, 5/2 Day or 0 Programmable
• For Single Stage, Multi-Stage and Heat Pump Systems • 5/1/1, 5/2 Day, 0 Programmable or Non-Programmable • Hardwired or Battery Powered