general infOrMatiOn
The Multiquip Model CX400 and PX400 submersible pumps 
are designed to pump water and is used for the draining 
(dewatering) of well casings construction sites, coffer dams, 
manholes, transformer vaults and excavations.
Its slim design, only 10 inches (25.4 cm.) in diameter allows 
it to fit easily inside casings and eliminates the need for 
larger, more costly casings. The pump is powered by a 1/2 
HP, 115-volt, single-phase motor for easy starting with a 
small 2,500-watt generator.
This  rugged  submersible  pump  is  loaded  with  features 
such as:
 
„
tHermal overload protection - Automatically 
shuts off the motor should it reach an unsafe operating 
temperature.
 
„
HeavY-dutY  liFting  Handle  -  Provides  and 
convenient and safe location to attach a lifting device.
 
„
Strain-relieF protector - Provides added safety 
in the event the operator should try lifting the pump from 
the electrical cord.
 
„
replaceable diScHarge port - Provides easy 
maintenance and lower repair costs.
 
„
double oil-lubricated Seal - provides positive 
lubrication if the pump should be left running dry. This 
helps prevent damage in the event the pump is run dry 
for short periods of time.
 
„
impeller - Abrasion resistance plastic minimizes wear 
and extends impeller life.
 
„
pump caSing - High strength plastic design makes  
pump a great choice in corrosive environments. Ideal for 
use in marine and certain chemical applications.
If the pump was used to pump water containing mud, silt, 
use clean water to flush out the pump after each use.
do not allow the pump to run dry for an extended period 
of time, as this will damage the pump. During maintenance, 
dry running is permissible but only for a few seconds. 
never lift the pump by its electrical power cord. alWaYS 
lift the pump by its carrying handle or attach a rope to the 
carrying handle.
A pump fully submerged in liquid will not freeze, unless 
the liquid freezes. 
do not allow a partially submerged 
pump to freeze. The expansion of water freezing in the 
volute may crack the pump, causing expensive repairs. If 
there is any danger of the pump being subjected to freezing 
temperatures, Lift the pump from water and allow it to drain 
thoroughly.
If the pump jams or the pump rotor locks for any reason, 
disconnect the pump from the power source immediately.  
Allowing the pump motor to cycle 
on and oFF under an 
overload condition can burn out the motor.
When replacement of nuts and bolts is required, use only 
recommended parts as referenced in the parts section of 
this manual. This pump uses metric threads. 
do not use 