Graco 332317C Manual De Usuario

Descargar
Página de 34
Troubleshooting 
26
332317C
Troubleshooting
Problem
Cause
Solution
Unit does not power on
Incorrect/loose wiring
Refer to Installation instructions, page 7.
Unit does not power on (DC models only)
Tripped external fuse due to internal 
component failure
Contact Graco Customer Service.
Tripped external fuse due to pumping 
non-cold weather lubricant in cold 
weather -13°F (-25°C) 
Replace lubricant with pumpable lubri-
cant, rated for environmental conditions 
and application. 
Replace fuse.
Unit does not power on (AC models only)
Tripped internal power supply fuse due to 
power supply failure
Contact Graco Customer Service.
Can’t set desired ON/OFF times
Allowable ON time: 1-30 minutes
Allowable OFF time: 1-24 hours
(in full minute or hour increments)
Adhere to allowable duty cycle. Contact 
Graco Customer Support if other duty 
cycles are required for application.
Unit is not operating based on the time 
that was programmed
Time entered was misinterpreted as MM 
instead of HH (or visa versa)
Verify the unit was programmed as 
intended, referencing programming 
instructions. 
Lubricant leaks past seal located on the 
bottom of the reservoir
Reservoir retaining tabs are cracked or 
broken
Replace reservoir.
Reservoir is being pressurized during fill-
ing
Ensure vent hole is not plugged.
If problem persists, contact Graco Cus-
tomer Service or your local Graco distrib-
utor for assistance.
Unit not pumping during ON cycle, but 
controller lights and functions
Failed motor
Replace unit.
Follower plate is not going down 
Air is trapped in the reservoir between 
the follower plate and lubricant
Add grease following Loading Grease 
instructions, page 19. Ensure air is 
purged.
Pump takes several minutes before it 
begins pumping 
Pumping non-cold weather lubricant in 
cold weather -13°F (-25°C) 
Increase pump on time.
Use grease suitable for temperature and 
conditions.
Dim display, unit is not operating
Tripped internal, resettable fuse due to 
internal component failure or short circuit 
condition
Verify manual run inputs have not cre-
ated a short circuit condition. Cycle 
power.
Unit indicates a cycle or pressure alarm 
before the lubrication cycle could com-
plete
The ON Time was not entered correctly
Refer to programming ON Time, page 
23.