Related Diagnostic Procedures
8-3
Related Diagnostic 
Procedures
When troubleshooting problems, you may have to perform minor 
procedures to help correct the problem. These procedures are described 
below. For more complex operations on the CoreBuilder 7000 family ATM 
switch, contact 3Com Technical Support.
Safety Precautions for Fiber Optics Connectors
Avoid touching all surfaces after cleaning the connectors, and keep all 
unused ports covered.
Vermeiden Sie das Berühren aller Oberflächen nach dem Säubern der 
Kontakte und verdecken Sie alle nicht benutzten Öffnungen.
Ne toucher aucune surface après le nettoyage des connecteurs et garder 
les pièces inutilisées couvertes.
Table 8-3   Diagnostic Procedures
Procedure
Action 
Checking fan 
operations
In case of system overheating, check that the power supply fan and the fans in the fan tray 
are operating. To check for fan movement in the CoreBuilder 7000 family ATM switch’s 
fan tray, pull a few modules from the chassis to view the fans on the left side of the 
system.
Cleaning dirty fiber 
optic cables
*
Fiber optic transceivers are sensitive optical devices that need to be handled carefully. If dirt 
collects on the fiber optic lens, you may notice that the LED for an ATM port link status 
does not light. You may also notice degraded performance of that port, indicated by an 
increase in the physical layer statistics count for that port.
To prevent dust from collecting on the fiber optic lens, keep the dust covers on the ports at 
all times when they are not in use. To clean a fiber optic lens, follow the procedure below:
Remove any accumulated dust or debris from the port or connector by blowing off all 
surfaces with a canned air duster.
Compressed gas is recommended, such as Chemtronics’ Ultrajet ® or the Triangle Tool 
Group’s Liqui-Too!™ Dust-A-Way. Do not use commercial compressed air or “house 
air” because of the risk of oil contamination.
Reconnect the cable to the port to see if the dusting corrected the problem.
If the LED still does not appear, or if it lights yellow, continue with steps 5 and 6.
Gently wipe the ports with a lint-free, non-abrasive, non-adhesive swab. Microswabs™ 
by Texwipe™ are recommended.
Gently wipe the connectors with a lint-free, non-abrasive wipe or pad. Texwipe™ pads 
are recommended.
* See safety precautions in next section.