Power Supply Module
4-3
Power Supply 
Module
The CoreBuilder 7000 family ATM switch provides a dual load-sharing 
power supply capability where the second unit can serve as a redundant 
power supply. For more information, see “Redundant Power Supply” on 
page 7-1
.
For certain combinations of installed interface cards, the second power 
supply cannot be used as a redundant supply (see “Providing Redundancy 
for Various Power Loads” on page 7-
6).
This section discusses the following topics:
Installing a Power Supply Module
Replacing a Redundant Power Supply Module
Installing a Power
Supply Module
To install a power supply module:
Orient the module so that its sides enter the guides on either side of the 
chassis slot.
Slide the module into the chassis until the face panel is flush with the 
enclosure.
Secure the screws on either side of the front panel.
If a redundant power supply is not installed in the second power supply 
slot, cover the slot with a blank panel for safety.
Replacing a
Redundant Power
Supply Module
This section describes how to replace a redundant power supply module. 
You can replace the redundant power supply without having to turn off 
the system (hot-swap). For more information on the operation of the 
redundant power supply module, see “Redundant Power Supply” on 
page 7-1
To replace a redundant power supply module:
Disconnect the power cord from the power supply.
Loosen the screws at the extreme right and left of the power supply, near 
the handles (refer to Figure 4-1). 
Grasp the handles of the redundant power supply you want to replace 
and pull them outward. This ejects the power supply. 
Remove the new power supply from its antistatic bag. Place the old 
power supply in the antistatic bag and set it aside in a safe place.